BACKGROUND

Aspheric intraocular lens (IOLs) implantation has been widely applied in cataract surgery. However, there is no consensus on the optimal guidance for the operations in IOLs implantation.

OBJECTIVE

This study evaluated the visual function of Chinese cataract patients six months after cataract surgery with two different guiding ideologies.

METHODS

We evaluated 50 patients (61 eyes) with implantation of different aspheric IOLs (SN60WF IOLs, ZCB00 IOLs, PY-60AD IOLs, AO IOLs) 6 months after cataract surgery. Twenty-four patients (30 eyes) under individual implantation were ascribed to group 1 and 26 patients (31 eyes) with randomized implantation were ascribed to the control group (group 2). Postoperatively parameters included monocular best-corrected visual acuity (BCVA), contrast sensitivity (CS), total spherical aberration Z (4, 0) at 5 mm pupil size, and patient satisfaction. The quality of life after operation was assessed through the National Eye Institute Visual Function Questionnaire-25 (NEI VFQ-25).

RESULTS

Six months after cataract operation, the contrast sensitivity with glare of group 1 at 2.5∘ was 0.697 ± 0.027, and 0.532 ± 0.049 in group 2. Besides, there was no significant difference at any other special frequency. The mean spherical aberration Z (4, 0) at 5 mm pupil size in group 1 was 0.015 ± 0.028 um, and in group 2 was 0.043 ± 0.109 um, with a significant difference (p< 0.01). The mean scores obtained from NEI VFQ-25 were not significantly different.

CONCLUSION

It is effective to implant aspheric IOLs individually according to preoperative corneal spherical aberration. Patients obtained better contrast sensitivity with glare at 2.5∘, but there was no significant difference in BCVA, contrast sensitivity at other special frequency, and subjective visual function.

Для цитирования: Duan Lian, Dang Guangfu, Ge Jinling, Gao Yang, Wang Lihua. Visual function assessment of Chinese cataract patients after individual aspheric intraocular lens implantation according to preoperative cornea spherical aberration.. Technology and health care : official journal of the European Society for Engineering and Medicine. 2023. DOI: 10.3233/thc-220154.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.