MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-022-02227-3

Медицинская библиотека · International ophthalmology · 2022

Outcomes of combined phacoemulsification/intraocular lens implantation and silicon oil removal.

Karimi Saeed, Nikkhah Homayoun, Farzanbakhsh Shayan, Karjou Zahra, Safi Sare

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the outcomes and complications of simultaneous silicon oil removal (SOR) and phacoemulsification and intra ocular lens implantation.

METHODS

In this retrospective non-comparative case series, the visual, refractive and anatomical outcomes of patients who underwent combined phacoemulsification/silicone oil removal (5700 centistokes) surgery between 2017 and 2019 in a single center were evaluated.

RESULTS

Forty-four eyes of 44 patients (eighteen males) were included. The mean age of the patients was 51.45 ± 11.59 years. The primary pathology was tractional retinal detachment (TRD) secondary to diabetic retinopathy in 36 eyes and rhegmatogenous retinal detachment (RRD) in 8 eyes. The median time period between silicone oil tamponade and removal was 9 months. There was no statistically significant difference between best corrected visual acuity (-0.14 ± 0.69 LogMAR, p= 0.19) and intraocular pressure (p= 0.26) before and after the surgery. Mean post-operative spherical equivalent (SE) at last visit was 0.36 ± 1.64 which was different from the target refraction (- 0.5D). After cataract/SOR surgery, one eye (2.3%) developed retinal re-detachment in RRD patient. Vitreous hemorrhage occurred in nine eyes (20.5%) which all had TRD as the primary pathology.

CONCLUSION

Combined phacoemulsification, silicone oil and IOL implantation removal surgery seems to be a safe and useful procedure with high success rate and acceptable visual, refractive and anatomical outcomes.

Для цитирования: Karimi Saeed, Nikkhah Homayoun, Farzanbakhsh Shayan, Karjou Zahra, Safi Sare. Outcomes of combined phacoemulsification/intraocular lens implantation and silicon oil removal.. International ophthalmology. 2022. DOI: 10.1007/s10792-022-02227-3.