DOI 10.1186/s12886-022-02372-4

Медицинская библиотека · BMC ophthalmology · 2022

Influence of implantation of diffractive trifocal intraocular lenses on standard automated perimetry.

Lee Jinhee, Mori Yosai, Minami Keiichiro, Miyata Kazunori

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

This prospective comparative study aimed to investigate the influence of diffractive trifocal intraocular lenses (IOLs) implantation on standard automated perimetry.

METHODS

Patients with no diseases affecting the visual field had undergone cataract surgery following the implantation of trifocal or monofocal IOLs from July 2019 to August 2020 were recruited. The normality of the anterior and posterior segments and absence of glaucomatous optic nerve cupping were confirmed preoperatively by slit-lamp examination. Standard automated perimetry was performed using Humphrey Visual Field 10-2 testing, 2-3 months after cataract surgery in only one eye per patient. The mean deviation (MD) and foveal sensitivity were compared between IOLs in eyes with acceptable reliability indices and best-corrected visual acuity of 20/25 or better.

RESULTS

Among the 83 eyes of the 83 patients included, 39 and 29 eyes eligible for perimetry analysis had trifocal and monofocal IOLs, respectively. The mean MD and foveal sensitivity in eyes with trifocal IOLs were significantly lower than those in eyes with monofocal IOLs (P < 0.021), with mean differences of 0.77 and 1.01 dB, respectively.

CONCLUSION

The comparison in nonglaucomatous eyes demonstrated that the influence of trifocal IOLs on standard automated perimetry was greater than that of monofocal IOLs.

Для цитирования: Lee Jinhee, Mori Yosai, Minami Keiichiro, Miyata Kazunori. Influence of implantation of diffractive trifocal intraocular lenses on standard automated perimetry.. BMC ophthalmology. 2022. DOI: 10.1186/s12886-022-02372-4.