CONCLUSIONS

Although there was a statistically significant relationship between the results of the vHIT and the caloric test, the limited strength of this relationship suggests that, for unilateral vestibular schwannoma (UVS), caloric testing and vHIT may provide complementary information on vestibular function.

OBJECTIVE

There is limited information that can be used to determine which of the video head impulse test (vHIT) and caloric test might be better used in the diagnosis and management of UVS. In this study, a group of participants with un-operated UVS was studied using both methods.

METHODS

The subjects' vestibular function was assessed using the vHIT and caloric testing. Tumour size was quantified using MRI and their balance disturbance assessed using the Jacobsen Dizziness Handicap Inventory (DHI).

RESULTS

Twenty of 30 subjects had an abnormal canal paresis according to the Jongkees' criterion (> 0.25); however, only 10/30 had an ipsilesional vHIT gain of <0.79. Canal paresis could be predicted from the ipsilesional and contralesional vHIT gains. Tumour size could also be predicted from the ipsilesional vHIT gain and canal paresis. However, DHI scores could not be predicted from the degree of canal paresis, vHIT gain, or the MRI measures.

Для цитирования: Tranter-Entwistle Isaac, Dawes Patrick, Darlington Cynthia L, Smith Paul F, Cutfield Nicholas. Video head impulse in comparison to caloric testing in unilateral vestibular schwannoma.. Acta oto-laryngologica. 2016. DOI: 10.1080/00016489.2016.1185540.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.