Geometric Fidelity of Magnetic Resonance Imaging and Computed Tomography-Derived Virtual 3D Models of Porcine Cadaver Mandibles: Conventional Versus Artificial Intelligence-Based Segmentation.

Ritschl Lucas M, Pippich Katharina, Herrmann Matthias, Deppe Herbert, Sculean Anton, Probst Monika, Probst Florian A

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: The workflow for virtual surgical planning (VSP) and the application of CAD/CAM (computer-aided design/computer-aided manufacturing) procedures are mainly based on computed tomography (CT) derived DICOM data sets. Alternatively, this study aims to preclinically illuminate the feasibility of a magnetic resonance imaging (MRI) based workflow and the impact of artificial intelligence (AI) based segmentation on the required fidelity on basic 3D geometry acquisition.

MATERIALS AND

METHODS

Porcine cadaver mandibles were imaged with CT and a T1-weighted MRI sequence. The resulting DICOM data sets were segmented conventionally (Mimics Medical 17.0, Materialize; Belgium) and with AI-based segmentation software (ImFusion Labels and Suite, Version 2.19.2, ImFusion; Germany). The four standard tessellation language (STL) files were superimposed with a corresponding reference model derived from an optic scan (Artec Space Spider, Artec 3D; Luxembourg) and the following parameters were analysed: Hausdorff distance (HD), mean surface distance (MSD), root mean square distance (RMSD), time.

RESULTS

In comparison to the reference model, all four parameters were significantly (P 0.001) better for the CT imaging and the AI-based segmentation. MRI-derived AI-based segmentation reached the fidelity of CT imaging data sets and conventional segmentation (HD, MSD, and RMSD each P >0.05).

CONCLUSION

The use of AI-based segmentation software proved to be useful and feasible for MRI-derived data sets, and generated the desired 3D geometry more quickly while maintaining the necessary quality. Nevertheless, the results for the CT were still better and remain yet the standard.

Для цитирования: Ritschl Lucas M, Pippich Katharina, Herrmann Matthias, Deppe Herbert, Sculean Anton, Probst Monika, Probst Florian A. Geometric Fidelity of Magnetic Resonance Imaging and Computed Tomography-Derived Virtual 3D Models of Porcine Cadaver Mandibles: Conventional Versus Artificial Intelligence-Based Segmentation.. Oral health & preventive dentistry. 2025. DOI: 10.3290/j.ohpd.c_2365.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.