MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s602008

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2026

A Retrospective Study: Comparative Visual Performance of Two Non-Diffractive Extended Depth-of-Focus Intraocular Lenses: TECNIS PureSee versus Clareon Vivity.

Kang Junha, Han Jeewon, Lee Chung Min, Park Nahyun, Lee Yea Eun, Eah Kyu Sang, Chung Ho Seok, Kim Jae Yong, Yeoh Ronald, Son Hyeck-Soo, Lee Hun

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare postoperative visual performance between two non-diffractive, extended depth-of-focus (EDoF) intraocular lenses (IOLs) - TECNIS PureSee and Clareon Vivity - by evaluating visual acuity, contrast sensitivity, and patient-reported outcomes.

METHODS

In this retrospective comparative study, 102 eyes (51 per group) received either the PureSee or Vivity IOL. Visual acuity at various distances, defocus curves, and contrast sensitivity under photopic and mesopic conditions were assessed at 2 months postoperatively. Patient satisfaction and visual disturbances were also evaluated.

RESULTS

Both the PureSee and Vivity IOL demonstrated comparable visual acuity at far and near distances, while the Vivity showing significantly better visual acuity at intermediate distances (P = 0.045). Contrast sensitivity was significantly higher in the PureSee group at higher spatial frequencies (P = 0.038). Patient satisfaction and spectacle independence were high and comparable in both groups. The Vivity group showed a trend toward fewer reports of glare and halo.

CONCLUSION

The Vivity IOL performed better at intermediate distances with fewer photic phenomena when compared with the PureSee IOL. The differences between these two EDoF IOLs may help in lens selection based on patient's visual demands and lifestyle.

Для цитирования: Kang Junha, Han Jeewon, Lee Chung Min, Park Nahyun, Lee Yea Eun, Eah Kyu Sang, Chung Ho Seok, Kim Jae Yong, Yeoh Ronald, Son Hyeck-Soo, Lee Hun. A Retrospective Study: Comparative Visual Performance of Two Non-Diffractive Extended Depth-of-Focus Intraocular Lenses: TECNIS PureSee versus Clareon Vivity.. Clinical ophthalmology (Auckland, N.Z.). 2026. DOI: 10.2147/opth.s602008.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.