MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/jcm11175210

Медицинская библиотека · Journal of clinical medicine · 2022

Transcatheter Mitral Valve-in-Valve Implantation with the Balloon-Expandable Myval Device.

Blasco-Turrión Sara, Serrador-Frutos Ana, Jose John, Sengotuvelu Gunasekaran, Seth Ashok, Aldana Victor G, Sánchez-Luna Juan Pablo, Gonzalez-Gutiérrez Jose Carlos, García-Gómez Mario, Gómez-Herrero Javier, Aristizabal Cristhian, San Román J Alberto, Amat-Santos Ignacio J

СтатьяПеревод пока не подготовлен

Аннотация

Background

The vast majority of transcatheter valve-in-valve (ViV) mitral procedures have been reported with the SAPIEN family. We aimed to report the preliminary experience with the Myval balloon-expandable device in this setting.

Methods

Multicenter retrospective study of high-risk surgical patients with mitral bioprosthesis degeneration undergoing transcatheter ViV implantation with Myval device.

Results

A total of 11 patients from five institutions were gathered between 2019 and 2022 (age 68 ± 7.8, 63% women). The peak and mean transvalvular gradients were 27 ± 5 mmHg and 14.7 ± 2.3 mmHg, respectively, and the predicted neo-left ventricular outflow tract (neo-LVOT) area was 183.4 ± 56 mm2 (range: 171 to 221 mm2). The procedures were performed via transfemoral access in all cases (through echocardiography-guided transeptal puncture (81.8% transesophageal, 11.2% intracardiac)). Technical success was achieved in all cases, with no significant residual mitral stenosis in any of them (peak 7.2 ± 2.7 and mean gradient 3.4 ± 1.7 mmHg) and no complications during the procedure. There were no data of LVOT obstruction, migration, or paravalvular leak in any case. Mean hospital stay was 3 days, with one major vascular complication and no stroke. At 6-month follow-up, there was one case with suboptimal anticoagulation presenting an increase in the transmitral gradients (mean 15 mmHg) that normalized after optimization of the anticoagulation, but no other relevant events.

Conclusions

Transseptal ViV mitral implantation with the balloon-expandable Myval device was feasible and safe avoiding redo surgery in high-risk patients with bioprosthesis degeneration.

Для цитирования: Blasco-Turrión Sara, Serrador-Frutos Ana, Jose John, Sengotuvelu Gunasekaran, Seth Ashok, Aldana Victor G, Sánchez-Luna Juan Pablo, Gonzalez-Gutiérrez Jose Carlos, García-Gómez Mario, Gómez-Herrero Javier, Aristizabal Cristhian, San Román J Alberto, Amat-Santos Ignacio J. Transcatheter Mitral Valve-in-Valve Implantation with the Balloon-Expandable Myval Device.. Journal of clinical medicine. 2022. DOI: 10.3390/jcm11175210.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.