MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12886-026-04820-x

Медицинская библиотека · BMC ophthalmology · 2026

Analysis of visual quality after implantation of diffractive multifocal intraocular lens Diff - aA in cataract patients.

Jingwen Zhang, Louxun Sun, Yifan Yang, Shanshan Du, Jingzhi Shao, Fengyan Zhang

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To explore the visual quality analysis of cataract patients after implantation of the aspheric diffractive multifocal intraocular lens (IOL) Diff-aA IOL.

METHODS

This was a prospective cohort study. From September 2024 to September 2025, 93 cataract patients (93 eyes) from the First Affiliated Hospital of Zhengzhou University were recruited. They were divided into two groups by the IOL models: the observation group (53 cases, 53 eyes) received the Diff-aA IOL (HumanOptics AG, Germany), and the control group (40 cases, 40 eyes) received the Tecnis ZMB00 IOL (Johnson&Johnson Vision, USA). At 1 and 3 months post-surgery, uncorrected far, intermediate, and near visual acuities were measured, and defocus curves were plotted. The iTrace was used to assess objective visual quality, and the VF−14-CN scale(Visual Function-14 (Chinese Version))was used for subjective evaluation.

RESULTS

The observation group had slightly lower uncorrected near vision than the control (P < 0.05), but better uncorrected intermediate vision (P < 0.001). One - month post-surgery defocus curves showed the control had better visual acuity at −3.50D (P = 0.004), while the observation group outperformed at −1.50D to −2.50D (P = 0.0043, P < 0.0001, P = 0.0263). At 3 months, similar results were found at −1.50D to − 2.50D (P < 0.0001 all). At 3 months, no significant differences were noted in total high-order aberration (THOA), average height of the modulation transfer function (MTF Avg Height), strehl ratio(SR), point spread function (PSF) (P > 0.05) or average VF−14 scores (P = 0.667) between the two groups. Halos were the most common optical interference.

CONCLUSION

Diff-aA aspheric diffractive multifocal intraocular lenses can provide good near and far vision and a certain degree of intermediate vision in the short term after surgery, achieving a relatively continuous visual range after surgery, with a high rate of spectacle independence and an acceptable incidence of adverse visual phenomena.

Для цитирования: Jingwen Zhang, Louxun Sun, Yifan Yang, Shanshan Du, Jingzhi Shao, Fengyan Zhang. Analysis of visual quality after implantation of diffractive multifocal intraocular lens Diff - aA in cataract patients.. BMC ophthalmology. 2026. DOI: 10.1186/s12886-026-04820-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.