Machine Learning-Based Image Reconstruction in Wearable CC-EIT of the Thorax: Robustness to Electrode Displacement.

Jeschke Jan, Ivanenko Mikhail, Smolik Waldemar T, Wanta Damian, Midura Mateusz, Wróblewski Przemysław

СтатьяПеревод пока не подготовлен

Аннотация

This study investigates the influence of variable electrode positions on image reconstruction in capacitively coupled electrical impedance tomography (CC-EIT) of the human thorax. Images were reconstructed by an adversarial neural network trained on a synthetic dataset generated using a tomographic model that included a wearable elastic band with 32 electrodes attached. Dataset generation was conducted using a previously developed numerical phantom of the thorax, combined with a newly developed algorithm for random selection of electrode positions based on physical limitations resulting from the elasticity of the band and possible position inaccuracies while putting the band on the patient's chest. The thorax phantom included the heart, lungs, aorta, and spine. Four training and four testing datasets were generated using four different levels of electrode displacement. Reconstruction was conducted using four versions of neural networks trained on the datasets, with random ellipses included and noise added to achieve an SNR of 30 dB. The quality was assessed using pixel-to-pixel metrics such as the root-mean-square error, structural similarity index, 2D correlation coefficient, and peak signal-to-noise ratio. The results showed a strong negative influence of electrode displacement on reconstruction quality when no samples with displaced electrodes were present in the training dataset. Training the network on the dataset containing samples with electrode displacement allowed us to significantly improve the quality of the reconstructed images. Introducing samples with misplaced electrodes increased neural network robustness to electrode displacement while testing.

Для цитирования: Jeschke Jan, Ivanenko Mikhail, Smolik Waldemar T, Wanta Damian, Midura Mateusz, Wróblewski Przemysław. Machine Learning-Based Image Reconstruction in Wearable CC-EIT of the Thorax: Robustness to Electrode Displacement.. Sensors (Basel, Switzerland). 2025. DOI: 10.3390/s25216543.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.