DOI 10.1016/j.jmir.2025.101911
Inter-rater concordance in the classification of COVID-19 in chest X-ray images using the RANZCR template for COVID-19 infection.
Аннотация
INTRODUCTION
The Royal Australian and New Zealand College of Radiologists (RANZCR) has developed a reporting template to assist in the categorization of COVID-19 in chest X-ray (CXR) images and the levels of COVID-19 infection. Whilst CXRs are reported by radiologists, radiographers are often the first to assess the CXRs, and have the potential to support immediate triaging of patients with COVID-19. However, inter-reader concordance in the use of this reporting template remains underexplored.
METHODS
70 CXR examinations comprising of the four categories in the RANZCR chest X-ray (CXR) COVID-19 reporting template were used for the study. These included: 'typical' (for COVID-19) (n = 30); 'indeterminate' (for COVID-19) (n = 20); 'other diagnoses favoured' (n = 10) and 'normal' (n = 10). These images were independently categorised using the RANZCR reporting template by three cohorts of readers: 12 radiologists, 13 registered radiographers, and 12 final-year radiography students. A Weighted Kappa (κw) was used to evaluate inter-reader agreement within and between the cohort of readers.
RESULTS
Radiologists demonstrated fair (κw = 0.32) to substantial (κw = 0.77) inter-reader agreement, and their overall inter-reader was moderate (κw = 0.56). Registered radiographers demonstrated no (κw = -0.01) to moderate agreement (κw = 0.59), and their overall agreement was fair (κw = 0.31). Fourth year student radiographers demonstrated slight (κw = 0.004) to substantial (κw= 0.8) agreement, with a moderate (κw = 0.47) overall agreement among final year student radiographers.
CONCLUSION
There are wide variations in the classification of the CXRs using the RANZCR reporting template. Overall, radiologists exhibit superior concordance in CXR categorization using the COVID-19 reporting template. Radiographers demonstrate wide variability, highlighting the need for enhanced education and training to standardise the triaging of these patients undergoing CXR imaging for COVID-19 symptoms.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.