A Real-Time Enzyme-Linked Aptamer Assay (RT-eELAA) for Rapid and Sensitive Detection of Viral Antigens in Saliva Using Electrochemical Readout.

Adhikari Bal Ram, Wang Qing, Li Jiuxing, Sen Payel, Zhang Zijie, Gu Jimmy, Salena Bruno J, Yamamura Deborah, Li Yingfu, Soleymani Leyla

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Despite the need for reliable rapid antigen tests for infectious disease diagnostics, tests that combine rapid answer-to-result times with high sensitivity and specificity remain elusive. A major challenge in developing such tests is the loss of performance of analytical assays in clinical samples. Herein, we developed a rapid antigen test based on a real-time electrochemical sandwich assay for detecting SARS-CoV-2 and Influenza A in saliva. This assay used aptamers for both target capture and signal transduction and produced limits of detection of 301 and 743 copies/mL for SARS-CoV-2 and Influenza A, respectively. When evaluating this assay with clinical saliva samples, we encountered major issues in distinguishing between positive and negative samples. In response, we developed a revised method to interrogate each clinical sample with a pair of electrochemical detectors modified, respectively, with a functional aptamer or a nonfunctional aptamer mutant. This method enabled us to normalize the signal response measured from each clinical sample with a reference signal, overcoming the previously encountered challenge and resulting in a clinical sensitivity of 100% and a specificity of 100% when analyzing 20 saliva samples that were collected and tested for COVID-19.

Для цитирования: Adhikari Bal Ram, Wang Qing, Li Jiuxing, Sen Payel, Zhang Zijie, Gu Jimmy, Salena Bruno J, Yamamura Deborah, Li Yingfu, Soleymani Leyla. A Real-Time Enzyme-Linked Aptamer Assay (RT-eELAA) for Rapid and Sensitive Detection of Viral Antigens in Saliva Using Electrochemical Readout.. Analytical chemistry. 2025. DOI: 10.1021/acs.analchem.5c02555.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.