Early Safety and Feasibility Study of a Novel Transcatheter Aortic Valve With Polymeric Leaflets.

Zhang Xiaochun, Jin Qinchun, Pan Wenzhi, Li Wei, Wang Bin, Wang Yan, Yang Hongbo, Zhu Da, Pan Xiang Bin, Li Bo, Chen Shasha, Long Yuliang, Zhang Lei, Zhang Weijing, Ren Yun, Chen Haiyan, Yang Xue, Qian Juying, Zhou Daxin, Ge Junbo

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Transcatheter aortic valve replacement is a promising alternative treatment for patients with severe aortic stenosis (AS), but uncertainties remain regarding its long-term durability.

OBJECTIVES

This study aimed to evaluate the safety and feasibility of Sikelia transcatheter heart valve with polymeric leaflets in AS.

METHODS

In this first-in-human, prospective, nonrandomized, single-arm, multicenter study, patients with severe symptomatic AS eligible for the novel valve were recruited. Clinical outcomes and hemodynamic performance were reported at discharge and 30-day, 6-month, and 1-year follow-up.

RESULTS

Twelve patients (73.75 ± 7.28 years, 25% female, mean Society of Thoracic Surgeons score 4.51% [4.07%-4.87%], 66.67% bicuspid valve) were enrolled. Procedural success was achieved in 83.33% (1 fully device retrieval and 1 death due to coronary obstruction). All patients successfully underwent transcatheter aortic valve replacement were in NYHA functional class I/II at the 30-day follow-up, and significant improvement was shown in 6-minute walk distance and Kansas City Cardiomyopathy Questionnaire score (all P < 0.001). At 1 year, the effective orifice area (2.31 ± 0.33 cm2 vs 0.82 ± 0.14 cm2) and mean pressure gradient (6.33 ± 2.54 mm Hg vs 47.50 ± 13.82 mm Hg) improved substantially, so did those in bicuspid patients (all P < 0.001). No moderate/severe paravalvular leakage was recorded, and computed tomography scans revealed no evidence of subclinical leaflet thrombosis during follow-up. After discharge, no patients reported death, stroke, new pacemakers, or valve-related reintervention.

CONCLUSIONS

The preliminary outcomes of the novel transcatheter heart valve demonstrated a favorable hemodynamic performance with an acceptable safety profile at 1 year. Long-term follow-up is warranted to assess its durability in treating patients with AS.

Для цитирования: Zhang Xiaochun, Jin Qinchun, Pan Wenzhi, Li Wei, Wang Bin, Wang Yan, Yang Hongbo, Zhu Da, Pan Xiang Bin, Li Bo, Chen Shasha, Long Yuliang, Zhang Lei, Zhang Weijing, Ren Yun, Chen Haiyan, Yang Xue, Qian Juying, Zhou Daxin, Ge Junbo. Early Safety and Feasibility Study of a Novel Transcatheter Aortic Valve With Polymeric Leaflets.. JACC. Asia. 2026. DOI: 10.1016/j.jacasi.2025.10.032.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.