MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/hpc.0000000000000415

Медицинская библиотека · Critical pathways in cardiology · 2026

Sirolimus-Coated Versus Paclitaxel-Coated Balloons for Coronary Artery Disease: A Grade Assessed Systematic Review and Meta-Analysis.

Sajjad Fatima, Khattak Asad Iqbal, Farhan Kanza, Arshad Ayesha, Afridi Abdullah, Ali Muhammad Abdullah, Shahid Iqra, Imtiaz Zeeshan, Naveed Hammad, Alam Umama, Henna Fathimathul, Riaz Zoya, Khattak Fazia, Waqas Saad Ahmed, Ahmed Raheel

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

Despite advances in percutaneous coronary procedures, in-stent restenosis remains a significant challenge. Although sirolimus- and paclitaxel-coated balloons are promising alternatives, their comparative safety and efficacy remain uncertain. PubMed, Embase, and Cochrane databases were searched using relevant keywords from inception until August 2025. A total of 11 studies (7 randomized controlled trials and 4 observational cohort studies) were included, comprising 3633 participants overall. The primary outcomes assessed were target lesion revascularization and target lesion failure. Meanwhile, the Secondary outcomes included stent thrombosis, all-cause mortality, myocardial infarction, major adverse cardiovascular events, survival, binary restenosis, and angiographic endpoints (acute gain, diameter stenosis, in-segment late lumen loss, in-lesion late lumen loss, and in-segment minimal lumen diameter). Interstudy heterogeneity was assessed using I ² and X ² statistics ( I ²>50% = significant heterogeneity). Interstudy heterogeneity was low for most outcomes, including all primary clinical endpoints, with moderate heterogeneity observed only for select angiographic measures (notably in-segment late lumen loss and diameter stenosis). Statistical analysis was conducted using R software and RStudio (version 4.4.2), with a P value of < 0.05 indicating statistical significance. This meta-analysis examined studies that compared paclitaxel-coated balloon (PCB) versus standard balloon [sirolimus-coated balloon (SCB)] angioplasty. Regarding primary outcomes, there were no notable variations in target lesion failure [risk ratio (RR), 1.08, 95% CI, 0.90-1.29, P = 0.36] or target lesion revascularization (RR, 1.16, 95% CI, 0.98-1.37, P = 0.08). With all aggregated estimates being nonsignificant, secondary outcomes such as stent thrombosis, all-cause mortality, myocardial infarction, major adverse cardiovascular events, and survival were similar between groups. Angiographic endpoints revealed no discernible variations in late lumen loss (in-lesion and in-segment), acute gain, or diameter stenosis. Nonetheless, the SCB group's minimal lumen diameter was significantly smaller than that of the PCB group (MD, -0.08 mm, 95% CI, -0.14 to -0.01, P = 0.02). In treating coronary in-stent restenosis, SCB and PCBs show similar overall safety and effectiveness; lesion-specific angiographic variations indicate that customized selection may improve patient outcomes.

Для цитирования: Sajjad Fatima, Khattak Asad Iqbal, Farhan Kanza, Arshad Ayesha, Afridi Abdullah, Ali Muhammad Abdullah, Shahid Iqra, Imtiaz Zeeshan, Naveed Hammad, Alam Umama, Henna Fathimathul, Riaz Zoya, Khattak Fazia, Waqas Saad Ahmed, Ahmed Raheel. Sirolimus-Coated Versus Paclitaxel-Coated Balloons for Coronary Artery Disease: A Grade Assessed Systematic Review and Meta-Analysis.. Critical pathways in cardiology. 2026. DOI: 10.1097/hpc.0000000000000415.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.