[Retroiridal implantation of a Verisyse™ iris claw lens: refractive outcome and individualized intraocular lens constants].
Аннотация
BACKGROUND
Evaluation of refractive predictability with retroiridal implantation of a Verisyse(TM) iris-claw lens (AMO) and optimization of the IOL-constants recommended by the manufacturer.
PATIENTS AND
METHODS
A retrospective study after retroiridal iris-claw lens implantation in the years 2007-2012 including 52 eyes of 50 patients with a lack of capsular support was carried out. Follow-up data was recorded on average 5 weeks after surgery. Demographic data, indications, accompanying diseases, biometrical data and refractive outcome were analysed and an individualization of the intraocular lens constants for the SRK/T-, Holladay-1, Hoffer-Q and Haigis-formula was carried out.
RESULT: Indications for retroiridal implantation of a Verisyse(TM) lens were IOL luxation (32.7 %), complicated primary cataract surgery (25.0 %), secondary IOL Implantation (19.2 %), lens exchange (19.2 %) and luxation of the crystalline lens (3.8 %). Accompanying diseases were pancreatic diabetes (21.2 %), rheumatic diseases (7.7 %), homocystinuria (1.9 %), pseudoexfoliation of lens capsule (23.1 %), traumata (23.1 %), secondary glaucoma (23.1 %), proliferative diabetic retinopathy (9.6 %) and age related macular degeneration (5.8 %). Optimized IOL constants were an A-constant of 116.8 for the SRK/T formula, a surgeon factor (Holladay1) of 0.8, a pACD (HofferQ) of 4,4 and an a0 constant of 0,49 for the Haigis formula. Postoperative deviation of target refraction was within ± 2 D in 84.6 % of the eyes.
CONCLUSION
The retroiridal Verisyse(TM) intraocular lens shows a broad spectrum of indications and achieves a good visual outcome. The previously published IOL constants show optimization potential due to the small number of cases.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.