MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mca.0000000000001602

Медицинская библиотека · Coronary artery disease · 2025

Comparative efficacy of polymer-free versus biodegradable-polymer drug-eluting stents in percutaneous coronary intervention: an updated systematic review and meta-analysis.

Jaramillo Sebastian, Pinilla Juan, Stabile Francesco, de Pontes Vinicius Bittar, Ibrahim Mohammad Cheikh, Donaldy Webster, Gomes Wilton

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

BACKGROUND

Biodegradable polymer drug-eluting stents (BP-DES) are currently used in percutaneous coronary intervention (PCI). Polymer-free drug-eluting stents (PF-DES) have the potential to mitigate any risk associated with BP-DES; however, the relative efficacy and safety of these interventions remain to be fully elucidated.

METHODS

A systematic search of PubMed, Embase, and Cochrane Central was performed from inception to January 2025 to identify randomized controlled trials and observational studies comparing PF-DES with BP-DES in patients undergoing PCI. Heterogeneity was assessed using the I ² statistic. A two-sided P value less than 0.05 was considered statistically significant. Prespecified subgroup analyses were conducted based on follow-up duration.

RESULTS

A total of seven randomized controlled trials (RCTs) and four observational studies comprising 11 954 patients were included, of whom 5947 (49.7%) received PF-DES. In the pooled analysis, no statistically significant differences were observed between PF-DES and BP-DES in terms of cardiac death [risk ratio: 1.12, 95% confidence interval (CI): 0.96-1.31, P  = 0.15], target lesion failure (risk ratio: 1.09, 95% CI: 0.81-1.46, P  = 0.58), stent thrombosis (risk ratio: 0.90, 95% CI: 0.58-1.41, P  = 0.64), target lesion revascularization (risk ratio: 1.28, 95% CI: 0.81-2.02, P  = 0.28), or target vessel revascularization (risk ratio: 1.05, 95% CI: 0.70-1.58, P  = 0.79). Likewise, no significant subgroup effect was observed regarding longer-term follow-up outcomes.

CONCLUSION

This meta-analysis found comparable safety and efficacy outcomes between PF-DES and BP-DES in patients undergoing PCI; however, further RCTs are needed to evaluate long-term outcomes and newer-generation stent models.

Для цитирования: Jaramillo Sebastian, Pinilla Juan, Stabile Francesco, de Pontes Vinicius Bittar, Ibrahim Mohammad Cheikh, Donaldy Webster, Gomes Wilton. Comparative efficacy of polymer-free versus biodegradable-polymer drug-eluting stents in percutaneous coronary intervention: an updated systematic review and meta-analysis.. Coronary artery disease. 2025. DOI: 10.1097/mca.0000000000001602.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.