MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2147/opth.s50499

Медицинская библиотека · Clinical ophthalmology (Auckland, N.Z.) · 2013

Safety and effectiveness of a glistening-free single-piece hydrophobic acrylic intraocular lens (enVista).

Packer Mark, Fry Luther, Lavery Kevin T, Lehmann Robert, McDonald James, Nichamin Louis, Bearie Brian, Hayashida Jon, Altmann Griffith E, Khodai Omid

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the safety and effectiveness of a single-piece hydrophobic acrylic intraocular lens (IOL; enVista model MX60; Bausch & Lomb, Rochester, NY, USA) when used to correct aphakia following cataract extraction in adults.

METHODS

This was a prospective case series (NCT01230060) conducted in private practices in the US. Eligible subjects were adult patients with age-related cataract amenable to treatment with standard phacoemulsification/extracapsular cataract extraction. With follow-up of 6 months, primary safety and effectiveness end points included the rates of US Food and Drug Administration (FDA)-defined cumulative and persistent adverse events and the percentage of subjects who achieved best-corrected visual acuity (BCVA) of 20/40 or better at final visit. To evaluate rotational stability, subjects were randomized (1:1:1:1) to have the lens implanted in one of four axis positions in 45° increments.

RESULTS

A total of 122 subjects were enrolled. The rate of cumulative and persistent adverse events did not significantly exceed historical controls, as per FDA draft guidance. At the final postoperative visit, all subjects (100%) achieved a BCVA of 20/40 compared with the FDA historical control of 96.7%. Rotation of the IOL between the two final follow-up visits was ≤5° for 100% of eyes, and refractive stability was demonstrated. A low evaluation of posterior capsule opacification score was demonstrated, and no glistenings of any grade were reported for any subject at any visit.

CONCLUSION

This study demonstrated the safety and effectiveness of the MX60 IOL. Favorable clinical outcomes included preserved BCVA, excellent rotational and refractive stability, no glistenings, and a low evaluation of posterior capsule opacification score.

Для цитирования: Packer Mark, Fry Luther, Lavery Kevin T, Lehmann Robert, McDonald James, Nichamin Louis, Bearie Brian, Hayashida Jon, Altmann Griffith E, Khodai Omid. Safety and effectiveness of a glistening-free single-piece hydrophobic acrylic intraocular lens (enVista).. Clinical ophthalmology (Auckland, N.Z.). 2013. DOI: 10.2147/opth.s50499.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.