MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2013.03.013

Медицинская библиотека · Ophthalmology · 2013

Selection of an initial contact lens power for infantile cataract surgery without primary intraocular lens implantation.

Trivedi Rupal H, Wilson M Edward

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To provide guidelines for the selection of an initial contact lens (CL) power based on the preoperative characteristics of the patient in eyes undergoing infantile cataract surgery without primary intraocular lens (IOL) implantation.

DESIGN

Cohort study.

PARTICIPANTS

Eyes were included if cataract surgery was performed without primary IOL implantation before 1 year of age, a SilSoft CL (Bausch & Lomb, Rochester, NY) was placed immediately after surgery, and postoperative refraction data were available within 1 month after surgery.

METHODS

The target CL power was calculated by using the postoperative refraction at the corneal plane for each eye. A regression formula was derived using the targeted CL power and the axial length (AL). The CL power also was estimated using various formulas. An A-constant was derived to estimate CL power using IOL power calculation formula.

MAIN OUTCOME MEASURES: Contact lens power.

RESULTS

Fifty eyes of 50 patients were analyzed. Age at the time of cataract surgery was 2.4 ± 1.7 months. Refraction at the corneal plane was 29.6 ± 4.4 diopters (D). Regression analysis revealed that CL power=84.4 - 3.2 × AL (R(2) = 0.82; P<0.001). Contact lens power can be estimated using an A-constant of 112.176 in the IOL power calculation formula. If a CL power of 32 D had been used, 22 (44%) of 50 eyes would have needed a replacement of CL.

CONCLUSIONS

We devised guidelines on selecting the initial CL power based on preoperative AL. The IOL power calculator also can help to estimate CL power. Refraction at the conclusion of surgery in infants may be difficult, and preoperative biometry can be used to estimate CL power.

FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

Для цитирования: Trivedi Rupal H, Wilson M Edward. Selection of an initial contact lens power for infantile cataract surgery without primary intraocular lens implantation.. Ophthalmology. 2013. DOI: 10.1016/j.ophtha.2013.03.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.