MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0326568

Медицинская библиотека · PloS one · 2025

Seeding amplification assay with Universal Control Fluid: Standardized detection of α-synucleinopathies.

Bsoul Remarh, Simonsen Anja H, Frederiksen Kristian S, Svenstrup Kirsten, Bech Sara, Salvesen Lisette, Hejl Anne-Mette, Rossi Marcello, Parchi Piero, Lund Eva L, Areškevičiūtė Aušrinė

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Seeding amplification assays, specifically the Real-Time Quaking-Induced Conversion method (RT-QuIC), have shown great diagnostic potential for α-synucleinopathies. Numerous research groups have demonstrated the method's high sensitivity and specificity using cerebrospinal fluid (CSF) samples and various RT-QuIC workflows. However, establishing a uniform and stably performing RT-QuIC protocol remains challenging. To address this, we established an RT-QuIC protocol with a Universal Control Fluid (UCF), which is simple to adopt, performs stably, and allows uniform preparation of both sample and control reactions. Firstly, we adapted and established a published 48-hour RT-QuIC protocol, including the in-house production of recombinant α-synuclein (rec α-syn), and evaluated its sensitivity and specificity through a blinded screening of an 81 CSF sample cohort consisting of Parkinson's disease (PD), dementia with Lewy bodies (DLB), Alzheimer's disease, motor neuron disease, multiple system atrophy, unidentified neurodegenerative diseases, and healthy controls. Additionally, we tested all CSF samples in three volumes to determine which volume provides the best diagnostic accuracy. The established RT-QuIC performs nearly equally well with 7 µL and 15 µL added CSF, resulting in 94% and 94.5% diagnostic accuracy, respectively. Secondly, we developed a UCF solution and tested its performance with the established RT-QuIC protocol. Results indicate that UCF, used in defined volume and concentration, standardizes the preparation of both sample and control reactions without compromising the assay's diagnostic accuracy and provides a stabilizing environment for the reactions, ensuring higher reproducibility. The established RT-QuIC protocol for pathologic α-synuclein detection in PD and DLB CSF samples is highly sensitive (92-96%) and specific (93-96%). Therefore, it is important that its adoption in clinical laboratories is uncomplicated and uniform. RT-QuIC with UCF simplifies, standardizes, and stabilizes the assay's performance and, thus, could be recommended as a standard protocol for accurate detection of α-synucleinopathies.

Для цитирования: Bsoul Remarh, Simonsen Anja H, Frederiksen Kristian S, Svenstrup Kirsten, Bech Sara, Salvesen Lisette, Hejl Anne-Mette, Rossi Marcello, Parchi Piero, Lund Eva L, Areškevičiūtė Aušrinė. Seeding amplification assay with Universal Control Fluid: Standardized detection of α-synucleinopathies.. PloS one. 2025. DOI: 10.1371/journal.pone.0326568.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.