m+Medelevator.RU
← Поиск публикаций
Stroke · 2017

Noninvasive Assessment of Oxygen Extraction Fraction in Chronic Ischemia Using Quantitative Susceptibility Mapping at 7 Tesla.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Uwano Ikuko, Kudo Kohsuke, Sato Ryota, Ogasawara Kuniaki, Kameda Hiroyuki, Nomura Jun-Ichi, Mori Futoshi, Yamashita Fumio, Ito Kenji, Yoshioka Kunihiro, Sasaki Makoto

Аннотация

BACKGROUND AND PURPOSE: The oxygen extraction fraction (OEF) is an effective metric to evaluate metabolic reserve in chronic ischemia. However, OEF is considered to be accurately measured only when using positron emission tomography (PET). Thus, we investigated whether OEF maps generated by magnetic resonance quantitative susceptibility mapping (QSM) at 7 Tesla enabled detection of OEF changes when compared with those obtained with PET.

METHODS: Forty-one patients with chronic stenosis/occlusion of the unilateral internal carotid artery or middle cerebral artery were examined using 7 Tesla-MRI and PET scanners. QSM images were obtained from 3-dimensional T2*-weighted images, using a multiple dipole-inversion algorithm. OEF maps were generated based on susceptibility differences between venous structures and brain tissues on QSM images. OEF ratios of the ipsilateral middle cerebral artery territory against the contralateral side were calculated on the QSM-OEF and PET-OEF images, using an anatomic template.

RESULTS: The OEF ratio in the middle cerebral artery territory showed significant correlations between QSM-OEF and PET-OEF maps (r=0.69; P<0.001), especially in patients with a substantial increase in the PET-OEF ratio of 1.09 (r=0.79; P=0.004), although showing significant systematic biases for the agreements. An increased QSM-OEF ratio of >1.09, as determined by receiver operating characteristic analysis, showed a sensitivity and specificity of 0.82 and 0.86, respectively, for the substantial increase in the PET-OEF ratio. Absolute QSM-OEF values were significantly correlated with PET-OEF values in the patients with increased PET-OEF.

CONCLUSIONS: OEF ratios on QSM-OEF images at 7 Tesla showed a good correlation with those on PET-OEF images in patients with unilateral steno-occlusive internal carotid artery/middle cerebral artery lesions, suggesting that noninvasive OEF measurement by MRI can be a substitute for PET.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты