m+Medelevator.RU
← Поиск публикаций
Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2019

Eye Movement Perimetry and Frequency Doubling Perimetry: clinical performance and patient preference during glaucoma screening.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Meethal Najiya Sundus Kadavath, Pel Johan J M, Mazumdar Deepmala, Asokan Rashima, Panday Manish, van der Steen Johannes, George Ronnie

Аннотация

PURPOSE: To evaluate the screening accuracy of an Eye Movement Perimetry (EMP) in comparison with Frequency Doubling Perimetry (FDP) and to investigate the patient preference and perception towards these visual field screening methods.

METHODS: A total of 104 healthy subjects (mean age (SD) of 48 (14) years) and 73 glaucoma patients (mean age (SD) of 52 (13) years) were recruited. All the participants underwent a comprehensive ophthalmic evaluation including the 24-2 SITA standard protocol on the Humphrey Field Analyzer (HFA). This was followed by the 26-point protocol in EMP and the C-20-1 protocol in FDP. During EMP, all subjects were instructed to fixate a central target and to look at the detected peripheral target, followed by refixation of the central target and Saccadic Reaction Time (SRT) towards each of the "seen" stimuli was calculated. Next, a questionnaire was administered to evaluate the patient preference and perception towards the perimetry techniques. Mean SRTs and Robin scores were used to plot Receiver Operating Characteristics (ROC) curves to determine the screening accuracies. From the questionnaire survey, the frequency distributions of the responses were calculated.

RESULTS: Robin score and SRT were significantly increased in glaucoma patients in comparison with the age-matched healthy subjects (p < 0.001). The ROC analysis revealed comparable Area Under the Curve (AUC) values (0.95, p = 0.81) with a specificity of 95.2% for FDP and 96.2% for EMP with a sensitivity of 87.7%. Thirty-seven percent of the older age group (≥ 40 years) and 65% of severe glaucoma patients showed preference for EMP over FDP.

CONCLUSIONS: This study results indicate that the customized protocol in EMP provides efficient and rapid means of screening visual field defects in glaucoma, which compared well with FDP. Elderly healthy participants and patients with moderate and severe glaucomatous defects preferred EMP as it permitted natural reflexive eye movements thereby resembling a real-life test setting.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты