Morphology of the optic nerve head in glaucomatous eyes with visual field defects in superior or inferior hemifield.

Longo Antonio, Avitabile Teresio, Uva Maurizio G, Bonfiglio Vincenza, Russo Andrea, Toro Mario D, Faro Salvatore, Reibaldi Michele

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the morphology of optic nerve head (ONH) and border tissue (BT) of Elschnig in glaucomatous eyes with visual field defects in superior or inferior hemifield.

METHODS

In a case-control study, we included 25 patients with superior arcuate scotoma, 25 patients with inferior arcuate scotoma, and 25 healthy controls. They received visual field testing, measurement of peripapillary retinal nerve fiber layer (RNFL) thickness, and ONH examination in a radial pattern with spectral-domain optical coherence tomography. In each ONH scan, the length of Bruch membrane opening (BMO) and BT were measured. Pattern deviation of 6 areas of the visual field and RNFL thickness in corresponding sectors was calculated.

RESULTS

Mean BMO length did not differ between groups. Compared with controls, glaucomatous eyes with superior scotoma had a greater BT length in inferior sectors (p<0.001), and eyes with inferior scotoma had a greater BT length in superotemporal sectors (p = 0.006). In both groups, a significant correlation was found between BT length and pattern deviation and RNFL thickness of corresponding sectors of superior and inferior hemifields.

CONCLUSIONS

In patients with arcuate scotoma in one hemifield, the length of the BT correlates with glaucomatous anatomical and functional damage.

Для цитирования: Longo Antonio, Avitabile Teresio, Uva Maurizio G, Bonfiglio Vincenza, Russo Andrea, Toro Mario D, Faro Salvatore, Reibaldi Michele. Morphology of the optic nerve head in glaucomatous eyes with visual field defects in superior or inferior hemifield.. European journal of ophthalmology. 2017. DOI: 10.5301/ejo.5001033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.