MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5797/jnet.cr.2021-0052

Медицинская библиотека · Journal of neuroendovascular therapy · 2021

A Case of Direct Carotid-Cavernous Fistulae Successfully Treated by Bidirectional Double Catheter Technique: A Technical Note.

Hamano Eika, Satow Tetsu, Hori Takamitsu, Takahashi Jun C, Kataoka Hiroharu

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Ruptured carotid-cavernous aneurysms (CCAs) are known to result in direct carotid-cavernous fistula (CCF). Although endovascular treatment is recognized as the first-line treatment for direct CCF, obliteration is sometimes difficult because of the high-flow shunt. In this report, we present a case of a direct CCF treated by the combination of transarterial and transvenous approaches.

CASE PRESENTATION: A 57-year-old woman presented with conjunctival chemosis, exophthalmos, and tinnitus. Ophthalmological examination revealed increased intraocular pressure. DSA demonstrated a direct CCF due to a right ruptured CCA with retrograde shunted flow through the superior ophthalmic vein (SOV), superficial middle cerebral vein, basal vein of Rosenthal, and middle temporal vein. Two microcatheters were guided into the shunt segment from the internal carotid artery and SOV. In addition, a balloon catheter was placed at the neck of the aneurysm to assist coiling. Coil embolization for the CCF was performed using two microcatheters in the opposite direction, which enabled compact and tight packing of the shunt segment with only six coils. The CCF was eliminated. Two-year-follow-up MRA revealed no recurrence.

CONCLUSION

The bidirectional double catheter technique is a useful approach to obliterate a shunt in a short segment with minimal coils.

Для цитирования: Hamano Eika, Satow Tetsu, Hori Takamitsu, Takahashi Jun C, Kataoka Hiroharu. A Case of Direct Carotid-Cavernous Fistulae Successfully Treated by Bidirectional Double Catheter Technique: A Technical Note.. Journal of neuroendovascular therapy. 2021. DOI: 10.5797/jnet.cr.2021-0052.