DOI 10.1016/j.wneu.2019.04.024

Медицинская библиотека · World neurosurgery · 2019

Carotid Artery Stenting in Acute Stroke Using a Microporous Stent Device: A Single-Center Experience.

Lamanna Anthony, Maingard Julian, Kok Hong Kuan, Barras Christen, Jhamb Ashu, Thijs Vincent, Chandra Ronil, Brooks Duncan Mark, Asadi Hamed

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Carotid artery stenting (CAS) is an established treatment for carotid artery stenosis, typically in a semielective or elective setting. The growth of mechanical thrombectomy for acute stroke has led to an increased use of emergent carotid artery stenting (eCAS). This single-center retrospective case series evaluates the safety and efficacy of eCAS using a dual-layer micromesh nitinol stent to treat carotid artery stenosis in the acute stroke setting.

METHODS

Ethics approval was granted by the institutional review board. Clinical data of all patients who underwent CAS using the Casper dual-layer micromesh nitinol stent system (MicroVention, Terumo, Tustin, California, USA) at a tertiary level 24-hour endovascular thrombectomy service over a 2-year period (June 2016-June 2018) were retrospectively obtained and reviewed.

RESULTS

Twenty eCAS procedures were performed in 19 patients over the study period. Most patients had tandem lesions (12/20; 60%). Median National Institute of Health Stroke Scale score on admission was 17 (interquartile range 9-22). Stent deployment was technically successful in all patients. Recanalization rate was 95%. Symptomatic intracranial hemorrhage occurred in 2 patients (10%), both resulting in death. No other procedure-related deaths occurred. Stent thrombosis occurred in 2 patients. One delayed embolic stroke occurred. No other stent-related complications occurred. Median National Institute of Health Stroke Scale score at 24 hours postprocedure was 3 (interquartile range 1-12). Six patients had a good clinical outcome (modified Rankin Scale score between 0 and 2) at 3- to 6-month follow-up (38%).

CONCLUSIONS

eCAS using the Casper stenting system is effective and technically feasible in the acute stroke setting, although the ideal antiplatelet and anticoagulation regime is not clearly established.

Для цитирования: Lamanna Anthony, Maingard Julian, Kok Hong Kuan, Barras Christen, Jhamb Ashu, Thijs Vincent, Chandra Ronil, Brooks Duncan Mark, Asadi Hamed. Carotid Artery Stenting in Acute Stroke Using a Microporous Stent Device: A Single-Center Experience.. World neurosurgery. 2019. DOI: 10.1016/j.wneu.2019.04.024.

Предметные рубрики MeSH