MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/rcm.70063

Медицинская библиотека · Rapid communications in mass spectrometry : RCM · 2026

Simultaneous Quantification of Twelve Endogenous HPA Axis Compounds by Protein Precipitation and HILIC-UPLC-MS/MS in a Mouse Model of Insomnia.

Li Jiale, Luo Tao, Su Dan, Huang Wei, Ai Zhifu, Yang Ming, Zhu Genhua, Ping Yuhui, Long Wei, Liu Yali, Song Yonggui

СтатьяПеревод пока не подготовлен

Аннотация

RATIONALE: Accurate quantification of neurotransmitters and hormones within the hypothalamic-pituitary-adrenal (HPA) axis is essential for elucidating their pathological roles in neurodegenerative diseases.

METHODS

In this study, a solid-phase extraction (SPE) combined with hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC-UPLC-MS/MS) method was developed for the simultaneous determination of 12 endogenous compounds in the HPA axis. The method was fully validated according to FDA standards.

RESULTS

All analytes showed good linearity over the concentration range of 0.19-19.53 ng/mL, with lower limits of quantification (LLOQs) ranging from 0.19 to 19.53 ng/mL. Accuracy (relative bias) and precision (relative standard deviation) were within ±15%. Matrix effects were evaluated (85.7%-114.3%), and extraction efficiencies were found to be satisfactory (89.1%-108.9%). Compared with other LC-MS-based techniques, this method effectively eliminates interference from endogenous substances by utilizing SPE columns.

CONCLUSIONS

The proposed method exhibited excellent performance in terms of linearity, precision, accuracy, stability, and matrix effects, demonstrating superior practicality and reliability for the analysis of complex biological samples.

Для цитирования: Li Jiale, Luo Tao, Su Dan, Huang Wei, Ai Zhifu, Yang Ming, Zhu Genhua, Ping Yuhui, Long Wei, Liu Yali, Song Yonggui. Simultaneous Quantification of Twelve Endogenous HPA Axis Compounds by Protein Precipitation and HILIC-UPLC-MS/MS in a Mouse Model of Insomnia.. Rapid communications in mass spectrometry : RCM. 2026. DOI: 10.1002/rcm.70063.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.