MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00261-025-05308-w

Медицинская библиотека · Abdominal radiology (New York) · 2025

Prospective pilot evaluation of dark borosilicate oral contrast media for the evaluation of the stomach and small bowel using CT.

Mileto Achille, Inoue Akitoshi, Mohammadinejad Payam, Coveler Andrew L, Lee Yong S, Leng Shuai, Johnson Matthew P, Sun Yuxin, Thomas John V, Yeh Benjamin M, Bruining David H, Fletcher Joel G

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate the feasibility of use of dark borosilicate oral contrast media (DBOCM) in abdominopelvic CT in comparison with conventional oral contrast media (COCM) in a multi-institutional setting.

METHODS

Patients with known or suspected inflammatory bowel disease (IBD) (Site A) or suspected peritoneal carcinomatosis (Site B), who had undergone initial standard-of-care CT using COCM (positive, n = 10; neutral n = 22), underwent research CT with DBOCM. Attenuation differences between bowel wall and lumen using COCM and DBOCM were measured. Three radiologists independently examined all examinations with COCM and DBOCM. Patient tolerance and safety were recorded. Bowel wall visualization, distention, distended bowel length, and radiologist preference for bowel visualization were rated. Imaging findings using both oral contrast media were recorded, and a final consensus evaluation was performed to evaluate whether additional findings detected with DBOCM were visible with COCM.

RESULTS

Thirty-two patients (IBD, n = 15; suspected peritoneal carcinomatosis, n = 17) were included. No severe adverse effects were seen with DBOCM. Compared to COCM, DBOCM yielded significantly higher attenuation differences between bowel wall and lumen (P < .001). Bowel wall visualization, distention, and distended bowel length was significantly higher from the stomach to the ileum using DBOCM (P < .001). DBOCM was preferred by each reader over COCM for all intestinal segments, but significance was not achieved in pooled results. Additional imaging findings were found in seven patients (22% [7/32]; 95% CI 9-40%) using DBOCM.

CONCLUSION

Compared to COCM, DBOCM yielded improved bowel wall visualization and distention, also revealing additional imaging findings.

Для цитирования: Mileto Achille, Inoue Akitoshi, Mohammadinejad Payam, Coveler Andrew L, Lee Yong S, Leng Shuai, Johnson Matthew P, Sun Yuxin, Thomas John V, Yeh Benjamin M, Bruining David H, Fletcher Joel G. Prospective pilot evaluation of dark borosilicate oral contrast media for the evaluation of the stomach and small bowel using CT.. Abdominal radiology (New York). 2025. DOI: 10.1007/s00261-025-05308-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.