Carbon dioxide field flooding reduces the hemodynamic effects of venous air embolism occurring in the sitting position.

Longatti Pierluigi, Marton Elisabetta, Feletti Alberto, Falzarano Marco, Canova Giuseppe, Sorbara Carlo

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Although the utility of the sitting position is undisputed for biomechanical and ergonomic reasons, it has been debated in recent years for its risks, particularly venous air embolism (VAE). In order to reduce the hemodynamic effect of VAE, we changed the composition of the surgical field air partially replacing nitrogen with carbon dioxide (CO2) that better dissolves in human tissues.

METHODS

First, we tested our method on a test dummy in the sitting position. Infrared CO2 sensors were placed close to the wound opening and on the facial mask of the surgeon. An oxygen sensor was connected to a computer for data recording (ALTAIR(®), MSA Safety). This model showed that 10 L/min CO2 flow provides efficient air displacement, maintaining safety for the surgeon. We reproduced the above-described surgical field environment in ten consecutive cases of posterior fossa surgery performed in the sitting position. A homogeneous group of ten patients operated in the sitting position with standard setting environment was used for control. We intraoperatively monitored VAE with trans-esophageal echocardiography (TEE), end-tidal CO2 (ETCO2), CO2 arterial pressure (PaCO2), and hemodynamic changes.

RESULTS

Although the percentage of VAE was 70% in both groups, hemodynamic effects occurred in 10% of cases in the study group and in 40% of cases in the control group.

CONCLUSIONS

Our preliminary study shows that a CO2-enriched sitting position surgical microenvironment significantly reduces the hemodynamic effects of VAE, more likely because arterial CO2 emboli are more soluble and consequently much better tolerated than air emboli.

Для цитирования: Longatti Pierluigi, Marton Elisabetta, Feletti Alberto, Falzarano Marco, Canova Giuseppe, Sorbara Carlo. Carbon dioxide field flooding reduces the hemodynamic effects of venous air embolism occurring in the sitting position.. Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery. 2015. DOI: 10.1007/s00381-015-2742-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.