[Significance of serological markers and virological marker for hepatitis E in rhesus monkey model].
Аннотация
OBJECTIVE
To evaluate the serological markers and biological marker in the diagnosis of hepatitis E infection in a rhesus monkey model.
METHODS
86 rhesus monkeys had been infected with different doses of HEV. Hence, they were taken sequential blood samples at intervals up to 86 weeks for 4 hepatitis E virus (HEV) specific antibody assays (E2-IgM, E2-IgG, GL-IgG, and YES-IgG), and nucleic acid assay.
RESULTS
All the animals produced E2-IgG and all but one also produced E2-IgM and excreted the virus in stool, whereas positive rate of GL-IgG and YES IgG were low and correlated with virus level. Hepatitis occurred over a period of 4 weeks (between 3 an 7 weeks) after infection. Virological marker occurred mainly during incubation period and declined rapidly after onset of hepatitis. Seroconversion of E2-IgM occurred before onset of hepatitis in 70% monkeys and declined rapidly up to 50% of peak value after 4 weeks. E2-IgM seroconversion was closely paralleled by E2-IgG; however, E2-IgG persisted in all animals for the entire duration of experiment of up to 86 weeks. Production of GL-IgG and YES-IgG was delayed by one week after the E2 antibodies, these antibodies showed a transient occurrence and seroprevalence declined to 50% of the peak value over a period of 12 weeks.
CONCLUSION
E2-IgM might be used as a suitable acute hepatitis E marker, and E2-IgG as a suitable epidemiological marker. The seroconversion or titer elevation of GL-IgG and YES-IgG antibodies probably used to confirm the infection. The viral markers are optional for early diagnosis.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.