PURPOSE: To present ocular findings in a patient who showed negative scotopic electroretinogram (ERG) and reduced ON response, but normal dark adaptation.

CASE: An 18-year-old Japanese male patient who complained of severe asthenopia. His corrected visual acuities were 1.2 in both eyes. His fundi were normal. He had normal contrast sensitivity and normal dark adaptation.

METHODS

The patients underwent ERG (including the standard protocol and photopic long flash recordings).

RESULTS

The amplitudes of the rod ERG b-wave were reduced. The scotopic standard combined ERG response showed negative configuration. The photopic response to long flash revealed the reduced b-wave (ON response), while the amplitude of the first peak of the d-wave (OFF response) was within the normal range.

CONCLUSIONS

Postsynaptic abnormalities in both the rod and cone ON-pathways, which are often found in patients with night blindness, were suggested in the ERG findings, but the dark adaptation of our patient was normal. Neuromuscular evaluation of the patient and ophthalmological evaluation, including ERG, of his parents were normal. To our knowledge, the ophthalmological and electrophysiological findings of our patient cannot be attributed to any known clinical entity.

Для цитирования: Tanimoto Naoyuki, Usui Tomoaki, Ichibe Mikio, Kuze Manami, Takagi Mineo, Hasegawa Shigeru, Sato Masahisa, Tanaka Keiko, Abe Haruki. Negative scotopic ERG and photopic ERG ON response impairment in a patient with normal dark adaptation.. Documenta ophthalmologica. Advances in ophthalmology. 2006. DOI: 10.1007/s10633-006-9026-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.