Convolutional neural network deep learning model accurately detects rectal cancer in endoanal ultrasounds.

Carter D, Bykhovsky D, Hasky A, Mamistvalov I, Zimmer Y, Ram E, Hoffer O

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Imaging is vital for assessing rectal cancer, with endoanal ultrasound (EAUS) being highly accurate in large tertiary medical centers. However, EAUS accuracy drops outside such settings, possibly due to varied examiner experience and fewer examinations. This underscores the need for an AI-based system to enhance accuracy in non-specialized centers. This study aimed to develop and validate deep learning (DL) models to differentiate rectal cancer in standard EAUS images.

METHODS

A transfer learning approach with fine-tuned DL architectures was employed, utilizing a dataset of 294 images. The performance of DL models was assessed through a tenfold cross-validation.

RESULTS

The DL diagnostics model exhibited a sensitivity and accuracy of 0.78 each. In the identification phase, the automatic diagnostic platform achieved an area under the curve performance of 0.85 for diagnosing rectal cancer.

CONCLUSIONS

This research demonstrates the potential of DL models in enhancing rectal cancer detection during EAUS, especially in settings with lower examiner experience. The achieved sensitivity and accuracy suggest the viability of incorporating AI support for improved diagnostic outcomes in non-specialized medical centers.

Для цитирования: Carter D, Bykhovsky D, Hasky A, Mamistvalov I, Zimmer Y, Ram E, Hoffer O. Convolutional neural network deep learning model accurately detects rectal cancer in endoanal ultrasounds.. Techniques in coloproctology. 2024. DOI: 10.1007/s10151-024-02917-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.