DOI 10.1097/00002341-200003000-00011
A comparative study of bovine pericardium (periguard) and homologous sclera as lower eyelid spacer graft analogs in New Zealand white rabbits.
Аннотация
PURPOSE: To compare bovine pericardium (Periguard; Bio-Vascular, Inc., St. Paul, MN, U.S.A.) and homologous sclera as spacer graft analogs in a rabbit model.
METHODS
A nonrandomized experimental animal study was conducted. Elliptical subconjunctival implants were placed in one lower eyelid each of 10 rabbits. Five rabbits received homologous sclera implants, and five received bovine pericardium implants. The rabbits were killed 7 weeks later, and the lower eyelids were examined clinically and histopathologically.
RESULTS
Rabbit eyelids implanted with Periguard had a more marked inflammatory reaction and more significant collagen lamellar disruption than eyelids implanted with homologous sclera, although clinically they appeared quite similar.
CONCLUSIONS
Although bovine pericardium elicited a more intense inflammatory response at the histopathologic level, both implants were similarly tolerated at the clinical level. These findings are consistent with animal and human investigations of bovine pericardium in other parts of the body, and warrant further studies into its potential use in the human eyelid.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.