MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.6c00503

Медицинская библиотека · Analytical chemistry · 2026

Label-Free Electrochemiluminescence Detection of Urinary AD7c-NTP Using Structurally Optimized Iridium(III) Complexes on Boron-Doped Diamond Electrodes.

Wang Tiantian, Zhou Yanli, Wang Beibei, Dai Yunyi, Liu Lantao, Dong Hui, Xu Maotian, Zhi Jinfang

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Evaluation of Alzheimer's disease-associated neuronal thread protein (AD7c-NTP) in urine holds significant potential as a noninvasive and accessible biomarker for the early diagnosis of Alzheimer's disease (AD). In this study, a novel label-free and ultrasensitive electrochemiluminescence (ECL) sensor for detection of AD7c-NTP was designed based on a structurally optimized iridium(III) complex ([(piq)2Ir(CH3CN)2]BF4) as the luminescent probe at a boron-doped diamond (BDD) electrode. After modifying the antibody on the surface of the amino-functionalized BDD electrode, AD7c-NTP molecules were first captured, and then a sandwich immunoassay system was constructed by introducing aptamer-modified gold nanoparticles (AuNPs). Subsequently, [(piq)2Ir(CH3CN)2]BF4 was intercalated into the DNA double-helical structure via electrostatic adsorption, thereby enabling ECL signal detection. Based on the metal-to-ligand charge transfer of iridium complexes at the π-π* energy level and the acceleration of electron transfer from the complexes to the BDD electrode by AuNPs, the established ECL immunosensor exhibited high sensitivity, with a linear range of 0.001-100 ng/mL and an ultralow detection limit of 17.7 fg/mL (S/N = 3). The practicability of the assay was confirmed by the test of AD7c-NTP in human urine, providing valuable information for early screening of AD.

Для цитирования: Wang Tiantian, Zhou Yanli, Wang Beibei, Dai Yunyi, Liu Lantao, Dong Hui, Xu Maotian, Zhi Jinfang. Label-Free Electrochemiluminescence Detection of Urinary AD7c-NTP Using Structurally Optimized Iridium(III) Complexes on Boron-Doped Diamond Electrodes.. Analytical chemistry. 2026. DOI: 10.1021/acs.analchem.6c00503.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.