MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7150/ijms.118430

Медицинская библиотека · International journal of medical sciences · 2025

Deep Learning Based on Automated Breast Volume Scanner Images for the Diagnosis of Breast Lesions: A Multicenter Diagnostic Study.

Liu Hui, Zhang Ying, Tan Bin, Yin Yi-Fei, Yan Li-Xia, Xiang Li-Hua, Shan Dan-Dan, Zhang Yun-Yao, Ding Shi-Si, Xu Guang, Zhou Bo-Yang, Shi Yi-Lei, Zhu Xiao-Xiang, Hu Jing-Liang, Sun Li-Ping, Xu Hui-Xiong, Zhang Yi-Feng

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

Objectives

To develop a deep learning (DL) model for the automated detection and diagnosis of breast cancer utilizing automated breast volume scanner (ABVS) images, and to compare its diagnostic performance with that of radiologists in screening ABVS examinations.

Methods

In this multicenter diagnostic study, ABVS data from 1,368 patients with breast lesions were collected across three hospitals between November 2019 and April 2024. The DL model (VGG19, DenseNet161, ResNet101, and ResNet50) was developed to detect and classify lesions. One-tenth of the cases from Hospital A were randomly selected as a fixed internal test set; the remaining data were randomly divided into training and validation sets at an 8:2 ratio. External test sets were derived from Hospitals B and C. Pathological findings served as the gold standard. Clinical applicability was assessed by comparing radiologists' diagnostic performance with and without DL model assistance.

Results

For breast cancer detection, the DL model achieved an area under the receiver operating characteristic curve (AUC) of 0.984 (95% CI: 0.965-0.995) on the internal test set, 0.978 (95% CI: 0.951-0.994) on the external test set 1 (Hospital B), and 0.942 (95% CI: 0.902-0.978) on the external test set 2 (Hospital C). The model demonstrated significantly higher sensitivity (98.2%) and specificity (90.3%) than junior radiologists (P < 0.05), while exhibiting comparable diagnostic reliability and accuracy to senior radiologists. Interpretation time was significantly reduced for all radiologists when using the DL model (P < 0.05).

Conclusion

The DL model based on ABVS images significantly enhanced diagnostic performance and reduced interpretation time, particularly benefiting junior radiologists.

Для цитирования: Liu Hui, Zhang Ying, Tan Bin, Yin Yi-Fei, Yan Li-Xia, Xiang Li-Hua, Shan Dan-Dan, Zhang Yun-Yao, Ding Shi-Si, Xu Guang, Zhou Bo-Yang, Shi Yi-Lei, Zhu Xiao-Xiang, Hu Jing-Liang, Sun Li-Ping, Xu Hui-Xiong, Zhang Yi-Feng. Deep Learning Based on Automated Breast Volume Scanner Images for the Diagnosis of Breast Lesions: A Multicenter Diagnostic Study.. International journal of medical sciences. 2025. DOI: 10.7150/ijms.118430.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.