MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ogla.2022.07.005

Медицинская библиотека · Ophthalmology. Glaucoma · 2022

The Strain Response to Intraocular Pressure Decrease in the Lamina Cribrosa of Patients with Glaucoma.

Czerpak Cameron A, Kashaf Michael Saheb, Zimmerman Brandon K, Quigley Harry A, Nguyen Thao D

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАКлиническое исследованиеПеревод пока не подготовлен

Аннотация

OBJECTIVE

To measure biomechanical strains in the lamina cribrosa (LC) of living human eyes with intraocular pressure (IOP) lowering.

DESIGN

Cohort study.

PARTICIPANTS

Patients with glaucoma underwent imaging before and after laser suturelysis after trabeculectomy surgery (29 image pairs; 26 persons).

INTERVENTION: Noninvasive imaging of the eye.

MAIN OUTCOME MEASURES: Strains in optic nerve head tissue and changes in depths of the anterior border of the LC.

RESULTS

Intraocular pressure decreases caused the LC to expand in thickness in the anterior-posterior strain (Ezz = 0.94 ± 1.2%; P = 0.00020) and contract in radius in the radial strain (Err = - 0.19 ± 0.33%; P = 0.0043). The mean LC depth did not significantly change with IOP lowering (1.33 ± 6.26 μm; P = 0.26). A larger IOP decrease produced a larger, more tensile Ezz (P < 0.0001), greater maximum principal strain (Emax; P < 0.0001), and greater maximum shear strain (Γmax; P < 0.0001). The average LC depth change was associated with the Γmax and radial-circumferential shear strain (Erθ; P < 0.02) but was not significantly related to tensile or compressive strains. An analysis by clock hour showed that in temporal clock hours 3 to 6, a more anterior LC movement was associated with a more positive Emax, and in clock hours 3, 5, and 6, it was associated with a more positive Γmax. At 10 o'clock, a more posterior LC movement was related to a more positive Emax (P < 0.004). Greater compliance (strain/ΔIOP) of Emax (P = 0.044), Γmax (P = 0.052), and Erθ (P = 0.018) was associated with a thinner retinal nerve fiber layer. Greater compliance of Emax (P = 0.041), Γmax (P = 0.021), Erθ (P = 0.024), and in-plane shear strain (Erz; P = 0.0069) was associated with more negative mean deviations. Greater compliance of Γmax (P = 0.055), Erθ (P = 0.040), and Erz (P = 0.015) was associated with lower visual field indices.

CONCLUSIONS

With IOP lowering, the LC moves either into or out of the eye but, on average, expands in thickness and contracts in radius. Shear strains are nearly as substantial as in-plane strains. Biomechanical strains are more compliant in eyes with greater glaucoma damage. This work was registered at ClinicalTrials.gov as NCT03267849.

Для цитирования: Czerpak Cameron A, Kashaf Michael Saheb, Zimmerman Brandon K, Quigley Harry A, Nguyen Thao D. The Strain Response to Intraocular Pressure Decrease in the Lamina Cribrosa of Patients with Glaucoma.. Ophthalmology. Glaucoma. 2022. DOI: 10.1016/j.ogla.2022.07.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.