Comparison of Clinical Outcomes Following Gel Stent Implantation via Ab-Externo and Ab-Interno Approaches in Patients with Refractory Glaucoma.

Gallardo Mark J, Vincent Logan R, Porter Matthew

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare clinical outcomes following gel stent implantation via ab externo and ab interno approaches in patients with refractory glaucoma.

PATIENTS AND

METHODS

This retrospective study included 203 eyes of 185 patients aged ≥45 years who underwent Xen gel stent implantation as a standalone procedure for medically uncontrolled glaucoma (intraocular pressure (IOP) ≥18 mmHg) despite maximum tolerable IOP-lowering medications. One hundred and five eyes underwent gel stent implantation via ab interno approach and 98 via ab externo. Patients with prior conjunctival-incisional glaucoma or cataract surgery were also included. Study parameters were reduction in IOP and number of IOP-lowering medications from baseline to 3, 6, 9 and 12 months postoperatively.

RESULTS

There were no statistically significant differences in the age, sex, preoperative IOP, number of IOP-lowering medications or cup-disc ratio between the ab interno and ab externo groups at baseline (p > 0.05). At all postoperative time points, mean IOP and percentage reduction from baseline were comparable in both groups (p > 0.05) except at postoperative 6 months when the outcomes were significantly better (p < 0.05) in the ab externo group. The rate of postoperative procedures (5-Fluorouracil injections and bleb needling), the incidence of numerical or clinical hypotony and adverse events were comparable in both groups (p > 0.05). The mean number of IOP-lowering medications was comparable in both groups at all time points.

CONCLUSION

The Xen gel stent, whether implanted ab interno or ab externo, is effective in reducing IOP and dependence on topical medications in eyes with refractory glaucoma. The stent may be used in both phakic and pseudophakic patients and is a reasonable option for patients with prior failed trabeculectomy.

Для цитирования: Gallardo Mark J, Vincent Logan R, Porter Matthew. Comparison of Clinical Outcomes Following Gel Stent Implantation via Ab-Externo and Ab-Interno Approaches in Patients with Refractory Glaucoma.. Clinical ophthalmology (Auckland, N.Z.). 2022. DOI: 10.2147/opth.s354038.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.