MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2474126419895691

Медицинская библиотека · Journal of vitreoretinal diseases · 2019

Outcomes and Complications of Concurrent Pars Plana Vitrectomy and Scleral-Fixated Intraocular Lens Placement Using Gore-Tex Suture.

Day H Russell, Durrani Alia K, Kim Stephen J, Patel Shriji

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The authors aim to describe the visual outcomes and postoperative complications of concurrent pars plana vitrectomy and scleral-fixated intraocular lens (IOL) placement using Gore-Tex suture.

METHODS

A retrospective review of medical records was performed on 27 eyes of 27 patients undergoing concurrent pars plana vitrectomy and scleral-fixated IOL with Gore-Tex suture. Outcome measures were change in preoperative and postoperative visual acuity, final manifest refraction, and incidence of intraoperative and postoperative complications.

RESULTS

The mean age was 69.2 ± 11.3 years; there were 16 male patients (59%). The duration of follow-up ranged from 33 to 576 days with a mean of 200 ± 143 days. All patients received Bausch + Lomb Akreos AO60 IOL. The overall mean best-corrected visual acuity in Snellen equivalent improved from 20/276 preoperatively to 20/44 postoperatively (P < .001). The mean postoperative manifest spherical equivalent refraction was -0.35 ± 1.34 diopters (D). Seventy-five percent of eyes were ± 1.0 D of target refraction. Postoperative complications included corneal edema (26.0%), ocular hypertension (25.9%), hypotony (7.4%), cystoid macular edema (7.4%), vitreous hemorrhage (7.4%), and hyphema (3.7%). No cases of suture breakage, IOL dislocation, retinal detachment, or uveitis-glaucoma-hyphema syndrome were identified.

CONCLUSIONS

The use of Gore-Tex suture for posterior chamber IOL fixation resulted in favorable outcomes. No suture-related complications occurred during the follow-up period. Final refraction in this setting is typically within ± 1.0 D of target.

Для цитирования: Day H Russell, Durrani Alia K, Kim Stephen J, Patel Shriji. Outcomes and Complications of Concurrent Pars Plana Vitrectomy and Scleral-Fixated Intraocular Lens Placement Using Gore-Tex Suture.. Journal of vitreoretinal diseases. 2019. DOI: 10.1177/2474126419895691.
Подготовка и перевод публикации