Transcatheter mitral valve implantation via transapical approach: an early experience.
Аннотация
OBJECTIVES
As many as 50% of patients with severe symptomatic mitral valve regurgitation are denied surgical valve replacement or repair due to high operative risk. We describe an early series of cases of transcatheter implantation with a CardiAQ™ mitral valve via a transapical approach.
METHODS
Three consecutive patients with an Society of Thoracic Surgeons (STS) mortality score of >22% were selected for transcatheter mitral valve implantation (TMVI) on compassionate grounds. All patients were elderly, had severe mitral regurgitation (MR), were in Class IV heart failure and deemed unsuitable for the MitraClip. Two of the patients had functional MR in the setting of ischaemic cardiomyopathy with left ventricular ejection fraction (LVEF) <40%, deemed while the remaining patient had chordal rupture with extensive anterior leaflet flail (preserved LVEF). Comorbidities included previous coronary artery bypass surgery (n = 2), severe pulmonary hypertension (n = 1) and moderate to severe chronic renal failure (n = 3). A CardiAQ mitral valve was implanted using fluoroscopy and transoesophageal (TEE) guidance via a standard transapical approach.
RESULTS
Accurate prosthesis positioning and deployment with immediate elimination of the MR was achieved in all 3 cases. Two patients made full clinical recovery and were discharged home. Post-procedural TEE performed on Days 1, 30 and 60 days showed good valve function, stable valve position and minimal LVOT gradient. One patient expired on the postoperative day 9 due to pneumonia.
CONCLUSIONS
TMVI using the CardiAQ™ device via a transapical approach is feasible and effective.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.