MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euu333

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2015

The impact of frailty in older patients with non-ischaemic cardiomyopathy after implantation of cardiac resynchronization therapy defibrillator.

Dominguez-Rodriguez Alberto, Abreu-Gonzalez Pedro, Jimenez-Sosa Alejandro, Gonzalez Julia, Caballero-Estevez Natalia, Martín-Casañas Felisa Vanesa, Lara-Padron Antonio, Aranda Juan M

Клиническое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

AIMS: Frailty status impacts the prognosis in older patients with heart disease. However, frailty status impact is unknown in patients with non-ischaemic cardiomyopathy after cardiac resynchronization therapy (CRT).

METHODS AND

RESULTS

Functional measures of baseline frailty and clinical data were collected for all patients with non-ischaemic cardiomyopathy before CRT defibrillator (CRT-D) implantation. The level of frailty was assessed using the Fried and Walston definition. Cox proportional hazard regression models were used to examine the association between baseline frailty and decompensated heart failure (HF) at the 12 months follow-up. The cohort study consisted of 102 patients with a mean age of 73 ± 4 years, 53% of which were male patients. Twenty-nine patients (28%) were classified as frail before CRT-D implantation. Twenty-seven patients experienced decompensated HF after CRT-D implantation at the 12-month follow-up. In the non-frail group, 12 of 73 patients (16.4%) experienced episodes of decompensated HF. In contrast, 15 of 29 (55.6%) frail patients experienced higher proportions of decompensated HF (P < 0.001). Patients who were frail (hazard ratio 4.55, 95% confidence interval 1.726-12.013) were at increased risk for the decompensated HF (P for trend = 0.002) compared with those who were not frail.

CONCLUSION

Frailty is a strong predictor of adverse post-implantation outcome in patients with non-ischaemic cardiomyopathy undergoing CRT-D.

Для цитирования: Dominguez-Rodriguez Alberto, Abreu-Gonzalez Pedro, Jimenez-Sosa Alejandro, Gonzalez Julia, Caballero-Estevez Natalia, Martín-Casañas Felisa Vanesa, Lara-Padron Antonio, Aranda Juan M. The impact of frailty in older patients with non-ischaemic cardiomyopathy after implantation of cardiac resynchronization therapy defibrillator.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2015. DOI: 10.1093/europace/euu333.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.