DOI 10.1093/europace/euu326

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2014

Substrate-guided ablation of haemodynamically tolerated and untolerated ventricular tachycardia in patients with structural heart disease: effect of cardiomyopathy type and acute success on long-term outcome.

Proietti Riccardo, Essebag Vidal, Beardsall Jessica, Hache Philip, Pantano Alfredo, Wulffhart Zaev, Juta Rasna, Tsang Bernice, Joza Jacqueline, Nascimento Thais, Pegoraro Vagner, Khaykin Yaariv, Verma Atul

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: The purpose of this study was to evaluate the outcomes of purely substrate-guided ventricular tachycardia (VT) ablation in patients with non-ischaemic dilated cardiomyopathy (NIDCM) and ischaemic cardiomyopathy (ICM) and the impact of acute procedural success on long-term outcome.

METHODS AND

RESULTS

One hundred and forty-two patients (65 ± 12 years old, 72% male) with ICM (n = 87) and with NIDCM (n = 55) underwent substrate-guided VT ablation. The ablation approach involved eliminating all LP regions and ablating all scar border zone regions with 10 or more out of 12 pace-matching. All patients were followed with regular implantable defibrillator interrogations for mean 641 ± 301 days. Complete acute success (no inducible VT) was achieved in 60 patients with ICM (69%) and in 29 patients with NIDCM (53%) (P = 0.03). Partial success (elimination of clinical VT only) was obtained in nine patients with ICM (10%) and in four patients with NIDCM (7%) (P = 0.14). Procedural failure (clinical VT still inducible) occurred in 18 patients within the ICM group (21%) and in 22 patients of the NIDCM (40%) (P = 0.04). Overall, 51 patients presented with recurrence of ventricular arrhythmias: 23 in the group with ICM (26%) and 28 in the group with NIDCM (51%) (P = 0.03). Long-term success was related to acute procedural outcome.

CONCLUSIONS

Substrate-guided ablation is an effective approach in the treatment of VT with long-term outcome directly related to acute procedural success. Success rates are significantly lower in patients with NIDCM compared with those with ICM.

Для цитирования: Proietti Riccardo, Essebag Vidal, Beardsall Jessica, Hache Philip, Pantano Alfredo, Wulffhart Zaev, Juta Rasna, Tsang Bernice, Joza Jacqueline, Nascimento Thais, Pegoraro Vagner, Khaykin Yaariv, Verma Atul. Substrate-guided ablation of haemodynamically tolerated and untolerated ventricular tachycardia in patients with structural heart disease: effect of cardiomyopathy type and acute success on long-term outcome.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2014. DOI: 10.1093/europace/euu326.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.