m+Medelevator.RU
← Поиск публикаций
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2014

Sex differences in implantable cardioverter-defibrillator implantation indications and outcomes: lessons from the Nationwide Israeli-ICD Registry.

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Amit Guy, Suleiman Mahmoud, Konstantino Yuval, Luria David, Kazatsker Mark, Chetboun Israel, Haim Moti, Gavrielov-Yusim Natalie, Goldenberg Ilan, Glikson Michael, Israeli Working Group on Pacing and Electrophysiology

Аннотация

AIMS: Implantable cardioverter-defibrillators (ICDs) improve survival in certain high arrhythmic risk populations. However, there are sex differences regarding both the utilization and the benefit of these devices. Using a prospective national ICD registry, we aim to compare the indications for ICD implantation as well as outcomes in implanted women vs. men.

METHODS AND RESULTS: All subjects implanted with an ICD or cardiac resynchronization therapy with a defibrillator (CRTD) in Israel between July 2010 and February 2013 were included. A total of 3544 subjects constructed the baseline cohort, of whom 615 (17%) were women. Women had the same age (64 years) and rate of secondary prevention indication (26%) as men. However, women were more likely than men to have significant heart failure symptoms (52 vs. 45%), QRS > 120 ms (41 vs. 36%), and a higher rate of non-ischaemic cardiomyopathy (54 vs. 21%, all P values <0.05). Using multivariate analysis, women were more likely to undergo CRTD implantation (odds ratio = 1.8, P < 0.01). Follow-up data were available for 1518 subjects with a mean follow-up of 12 months. During follow-up, there were no significant differences among genders in the rate of any single or the combined outcomes of appropriate device therapies, heart failure admissions, or death. First-year re-intervention rate was double among women (5.6 vs. 3.0%, P < 0.01).

CONCLUSION: In real-world setting, women implanted with an ICD differ significantly from men in their baseline characteristics and in the use of CRTD devices. These, however, did not translate into outcome differences.

Предметные рубрики MeSH