MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/heartjnl-2013-305002

Медицинская библиотека · Heart (British Cardiac Society) · 2014

Application of a mortality risk score in a general population of patients with an implantable cardioverter defibrillator (ICD).

Schaer Beat A, Kühne Michael S, Blatter David, Osswald Stefan, Sticherling Christian

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

The implantable cardioverter defibrillator (ICD) is very effective in the prevention of sudden cardiac death, but its benefit is impaired by competing risks. A simple risk model to predict mortality was designed for patients with primary prevention and ischaemic cardiomyopathy. We aimed to apply this score to a general ICD population.

METHODS

This retrospective registry study included all patients in whom an ICD was implanted at a tertiary referral hospital. Risk factors were age >70 years, QRS width >120 ms, atrial fibrillation, New York Heart Association Functional Classification class >2 and glomerular filtration rate <60 mL/min/1.73 m(2). Kaplan-Meier curves were constructed according to the presence of 0, 1, 2 and >2 risk factors.

RESULTS

The cohort consists of 1032 patients, 881 (86%) were men, mean age was 61±14 years and mean follow-up 66±46 months. 256 patients (25%) died 58±41 months after implant. The setting was secondary prevention in 498 patients (48%). No risk factors was present in 32% of patients, 1 in 27%, 2 in 20% and >2 in 21%, respectively. There was a significant and comprehensible relation between risk score and mortality. Cumulative survival was 82% in patients with 0 risk factors, 63% in those with 1, 41% in those with 2 and 23% in those with >2 risk factors (p < 0.0001). ICD therapies were documented in 421 patients (41%) without correlation to risk factors.

CONCLUSIONS

In a mixed population of primary and secondary preventive ICD carriers, application of a simple risk score predicts long-term mortality but not appropriate use of the ICD.

Для цитирования: Schaer Beat A, Kühne Michael S, Blatter David, Osswald Stefan, Sticherling Christian. Application of a mortality risk score in a general population of patients with an implantable cardioverter defibrillator (ICD).. Heart (British Cardiac Society). 2014. DOI: 10.1136/heartjnl-2013-305002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.