m+Medelevator.RU
← Поиск публикаций
Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2013

Screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy: results of the European Heart Rhythm Association survey.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Proclemer Alessandro, Lewalter Thorsten, Bongiorni Maria Grazia, Svendsen Jesper Hastrup, Pison Laurent, Lundqvist Carina Blomström, Scientific Initiative Committee, European Heart Rhythm Association

Аннотация

The purpose of this EHRA survey was to examine the current clinical practice of screening and risk evaluation for sudden cardiac death in ischaemic and non-ischaemic cardiomyopathy with a focus on selection of candidates for implantable cardioverter-defibrillator (ICD) therapy, timing of ICD implantation, and use of non-invasive and invasive diagnostic tests across Europe. A systematic screening programme for sudden cardiac death existed in 19 out of 31 centres (61.3%). Implantation of ICDs according to the inclusion criteria of MADIT-II and SCD-HeFT trials was reported in 30 and 29% of centres, respectively, followed by MADIT-CRT (18%), COMPANION (16%), and combined MADIT and MUSTT (7%) indications. In patients with severe renal impairment, ICD implantation for primary prevention of sudden death was always avoided in 8 centres (33.3%), was not used only if creatinine level was >2.5 mg/dL in 10 centres (32.2%), and in patients with permanent dialysis in 8 centres (33.3%). Signal-averaged electrocardiography and heart rate variability were never considered as risk stratification tools in 23 centres (74.2%). Implantation of a loop recorder was performed in patients with borderline indications for ICD therapy in 6 centres (19.4%), for research purposes in 5 (16.1%), and was never performed in 20 (64.5%) centres. In conclusion, the majority of participating European centres have a screening programme for sudden cardiac death and the selection of candidates for ICD therapy was mainly based on the clinical risk stratification and not on non-invasive and invasive diagnostic tests or implantable loop recorder use.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты