MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/eur171

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2011

Asymmetric dimethylarginine predicts appropriate implantable cardioverter-defibrillator intervention in patients with left ventricular dysfunction.

Lehmann H Immo, Goette Andreas, Martens-Lobenhoffer Jens, Hammwöhner Matthias, Röhl Friedrich-Wilhelm, Bukowska Alicja, Ghanem Ali, Klein Helmut U, Bode-Böger Stefanie M

СтатьяПеревод пока не подготовлен

Аннотация

AIMS: More precise characterization of risk factors for occurring ventricular arrhythmia in patients (pts) with primary prevention implantable cardioverter-defibrillator (ICD) therapy is critical. We sought to investigate whether biomarkers of nitric oxide metabolism can predict the occurrence of ventricular tachyarrhythmias and might be used as risk markers in these pts.

METHODS AND

RESULTS

Plasma levels of l-arginine (Arg), asymmetric dimethylarginine (ADMA), symmetrical dimethylarginine (SDMA), monomethyl l-arginine, and nitrite/nitrate were examined in 106 consecutive pts (mean age 65 years, 97 male, mean LV-EF 24 ± 6%), with ischaemic (n= 82) or non-ischaemic cardiomyopathy (n= 24) who underwent ICD implantation for primary prevention of SCD. Appropriate ICD intervention was assessed during a mean follow-up of 344 days, and occurred in 18 of 106 (17%) pts. Asymmetric dimethylarginine plasma levels were significantly higher in pts with appropriate ICD intervention compared with those without any ICD intervention (0.564 ± 0.083 μmol/L vs. 0.513 ± 0.088 μmol; P= 0.027). The Arg/ADMA ratio was found lower in pts with appropriate ICD intervention than in those without ICD intervention (144.71 ± 32.50 vs. 175.29 ± 41.29; P= 0.002). Univariate Cox regression showed that ADMA (P = 0.028) and the Arg/ADMA ratio (P = 0.003) were associated with a higher incidence of appropriate ICD intervention. In a multivariable Cox regression analysis, an ADMA concentration above the 50th centile was independently associated with appropriate ICD intervention, revealing a hazard ratio (HR) of 4.21 (CI 95 %: 1.14-15.63; P = 0.028, Table 4). An Arg/ADMA ratio below the 25th centile had a HR of 3.83 (1.360-10.87; P = 0.011).

CONCLUSION

Asymmetric dimethylarginine and the Arg/ADMA ratio seem to be new biomarkers for the prediction of ventricular tachycardia/ventricular fibrillation episodes and of appropriate ICD intervention in pts with left ventricular ejection fraction dysfunction (LV-EF ≤ 35%), suggesting a value for risk stratification in these pts.

Для цитирования: Lehmann H Immo, Goette Andreas, Martens-Lobenhoffer Jens, Hammwöhner Matthias, Röhl Friedrich-Wilhelm, Bukowska Alicja, Ghanem Ali, Klein Helmut U, Bode-Böger Stefanie M. Asymmetric dimethylarginine predicts appropriate implantable cardioverter-defibrillator intervention in patients with left ventricular dysfunction.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2011. DOI: 10.1093/europace/eur171.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.