New Zealand primary implantable cardioverter defibrillator implantation and biventricular pacing guidelines.

Smith Warren, New Zealand Pacing and Electrophysiology Group

Consensus StatementСтатьяКлинические рекомендацииПеревод пока не подготовлен

Аннотация

Primary implantation of an implantable Cardioverter Defibrillator (ICD) is recommended for patients with ischaemic or non-ischaemic cardiomyopathy present for at least 3 months, with ejection fraction (EF) = or <30% measured = or >3 months after optimal heart failure treatment. Patients should be on maximal heart failure treatment as tolerated for = or >3 and preferably 6 months, and in New York Heart Association (NYHA) Class II or III. They should be = or >3 months remote from any revascularisation procedure or have no clinical symptoms or findings that would make them a candidate for revascularisation. There should be no associated disease reducing survival <18 months. Biventricular pacing is recommended for patients with an EF = or <35% after = or >6 weeks of optimal heart failure treatment, whose QRS duration is >149 ms or is 120-149 ms with two additional criteria for dyssynchrony (aortic pre-ejection delay >140 ms, interventricular mechanical delay >40 ms or delayed activation of the posterolateral left ventricular wall). They should be NYHA Class III, have had no major cardiovascular event in the prior 6 weeks and be in sinus rhythm. There should be no major comorbidity reducing survival <18 months or seriously impairing quality of life.

Для цитирования: Smith Warren, New Zealand Pacing and Electrophysiology Group. New Zealand primary implantable cardioverter defibrillator implantation and biventricular pacing guidelines.. The New Zealand medical journal. 2010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.