MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/eun208

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2008

Impact of interventricular lead distance and the decrease in septal-to-lateral delay on response to cardiac resynchronization therapy.

Buck Sandra, Maass Alexander H, Nieuwland Wybe, Anthonio Rutger L, Van Veldhuisen Dirk J, Van Gelder Isabelle C

Клиническое исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

AIMS: To investigate the influence of interlead distance and lead positioning on success of cardiac resynchronization therapy (CRT) in patients with advanced chronic heart failure and electrical dyssynchrony. Despite application of established selection criteria, 20-40% of the patients do not respond to CRT.

METHODS AND

RESULTS

We examined consecutive patients in whom CRT was implanted. Response to CRT was defined as a decrease in the left ventricular end-systolic volume >or=10% after 6 months. A comparison was made between patients who were responders to CRT and those who were non-responders. A univariate and stepwise multivariate logistic regression was performed with regard to predictors for response. Between January 2004 and January 2008, 174 patients who were treated with CRT were classified as responders [n = 95 (55%)] or non-responders [n = 79 (45%)]. Responders had a significantly larger horizontal interlead distance on the lateral thoracic X-ray [odds ratio (OR) 2.8 (1.2-6.6), P = 0.01], a septal-to-lateral delay >60 ms [OR 4.9 (2.0-11.4), P < 0.0001], non-ischaemic cardiomyopathy [OR 3.0 (1.3-6.9), P = 0.009], a left ventricular end-diastolic diameter <67 mm [OR 4.2 (1.8-9.9), P = 0.001], angiotensin-converting enzyme inhibitor use [OR 8.1 (1.7-38.2), P = 0.008], and no tricuspid valve insufficiency [OR 6.9 (1.3-35.5), P = 0.02]. Post-implantation responders had a significantly greater decrease in the intraventricular delay (septal-to-lateral delay 62 +/- 62 vs. 26 +/- 65 ms, P = 0.001), but not in the interventricular mechanical delay.

CONCLUSION

Larger interlead distance on the lateral thoracic X-ray, associated with positioning of the left ventricular lead in the posterior position, is associated with response after 6 months of follow-up. Furthermore, diminishing the septal-to-lateral delay is predictive for response.

Для цитирования: Buck Sandra, Maass Alexander H, Nieuwland Wybe, Anthonio Rutger L, Van Veldhuisen Dirk J, Van Gelder Isabelle C. Impact of interventricular lead distance and the decrease in septal-to-lateral delay on response to cardiac resynchronization therapy.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2008. DOI: 10.1093/europace/eun208.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.