m+Medelevator.RU
← Поиск публикаций
Letters in applied microbiology · 2012

Detection of human Enterovirus 71 reverse transcription loop-mediated isothermal amplification (RT-LAMP).

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Yaqing H, Wenping Z, Zhiyi Y, Xionghu W, Shouyi Y, Hong Y, Yingchun D, Guifang H

Аннотация

AIMS: In this study, a one-step, single-tube reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay was developed and validated for the detection of human Enterovirus 71 (EV71), the major aetiological agent of hand, foot and mouth disease (HFMD).

METHODS AND RESULTS: Reverse transcription loop-mediated isothermal amplification assay was optimized to amplify VP1 gene in the presence of a specific primer set and Bst DNA polymerase at an isothermal temperature of 63°C for 1 h. Amplified products were evaluated by visual inspection and agarose gel electrophoresis. The detection limit of RT-LAMP assay was 10(-5) 100 TCID50 or 160 copies in samples after RNA extraction, which was 10-fold higher in sensitivity than traditional reverse transcription polymerase chain reaction (RT-PCR). The specific positive amplification was only observed in EV71 strains, while no amplification was detected in other tested viruses. Digestion with a specific Escherichia coli restriction enzymes V (EcoR V) demonstrated that the amplified product was unique. A good correlation between RT-LAMP and real-time RT-PCR was observed on the basis of the analysis of 33 clinical samples.

CONCLUSIONS: Reverse transcription loop-mediated isothermal amplification is a novel, alternative microbiological approach for rapid, sensitive and specific detection of EV71 in HFMD.

SIGNIFICANCE AND IMPACT OF THE STUDY: Reverse transcription loop-mediated isothermal amplification assay is suitable for the diagnosis of EV71 infection as a routine diagnostic tool for HFMD because of fewer requirements of experimental conditions such as private clinics, field applications as well as an epidemiological survey in epidemic areas. RT-LAMP can also be used as an alternative method for EV71 detection.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты