DOI 10.1046/j.1365-2265.1999.00759.x

Медицинская библиотека · Clinical endocrinology · 1999

The continuous 7-hour intravenous dexamethasone suppression test in the differential diagnosis of ACTH-dependent Cushing's syndrome.

van den Bogaert D P, de Herder W W, de Jong F H, Biemond P, van der Lely A J, Lamberts S W

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

A recent report showing disappointingly low sensitivity and specificity for the oral high dose dexamethasone test in the differential diagnosis of Cushing's syndrome prompted us to re-evaluate the results obtained in our centre using the continuous 7-hour intravenous dexamethasone suppression test for this purpose.

PATIENTS: 105 patients with ACTH-dependent Cushing's syndrome were included in this study; 78 with Cushing's disease, 8 with ectopic ACTH-secreting tumours and 19 were classified as 'of unknown aetiology'.

RESULTS

In 74/78 (94.9%) of patients with Cushing's disease and in 3/8 (37.5%) patients with the ectopic ACTH syndrome, a plasma cortisol decrease > 190 nmol/l at 7 h as compared to baseline values was achieved in the continuous 7-hour intravenous dexamethasone suppression test. Using a plasma cortisol decrease > 190 nmol/l at 7 h as compared to baseline values as the cut-off value, the sensitivity and specificity of the continuous 7-hour intravenous dexamethasone suppression test for the diagnosis of Cushing's disease in patients with ACTH-dependent Cushing's syndrome were 94.9% and 62.5%, respectively.

CONCLUSIONS

In patients with ACTH-dependent Cushing's syndrome with a plasma cortisol decrease > 190 nmol/l at 7 h in the continuous 7-hour intravenous dexamethasone suppression test, additional localizing investigations such as bilateral simultaneous inferior petrosal sinus sampling and/or pentetreotide scintigraphy should be performed when no clearly discernible pituitary adenoma is observed on MRI studies. Patients with ACTH-dependent Cushing's syndrome with a plasma cortisol decrease < 190 nmol/l at 7 h in the continuous 7-hour intravenous dexamethasone suppression test should also undergo bilateral simultaneous inferior petrosal sinus sampling and/or pentetreotide scintigraphy to demonstrate the presence of a nonpituitary source of ACTH overproduction.

Для цитирования: van den Bogaert D P, de Herder W W, de Jong F H, Biemond P, van der Lely A J, Lamberts S W. The continuous 7-hour intravenous dexamethasone suppression test in the differential diagnosis of ACTH-dependent Cushing's syndrome.. Clinical endocrinology. 1999. DOI: 10.1046/j.1365-2265.1999.00759.x.

Предметные рубрики MeSH