MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/phpp.12500

Медицинская библиотека · Photodermatology, photoimmunology & photomedicine · 2019

Linear and exponential sunscreen behaviours as an explanation for observed discrepancies in sun protection factor testing.

Trullàs Carles, Granger Corinne, Lim Henry W, Krutmann Jean, Masson Philippe

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

In vivo testing of sun protection factor (SPF) values can show considerable interlaboratory variability. We studied the underlying reasons and clinical implications.

METHODS

Following the ISO 24444:2010 SPF testing method, seven contract research organizations (CROs) tested eight sunscreens marketed as SPF50 or SPF50+ and the reference SPF15 sunscreens P2 and P3 and SPF43 P6. We analysed differences in the products and CRO testing methods with regard to SPF variability. We tested the erythema prevention capacity of five of the products in subjects exposed to high doses of natural sunlight in Mauritius.

RESULTS

Sun protection factor values varied dramatically between different CROs for some, but not all of the sunscreens. Those with the largest variability had an SPF50+, and their SPF values differed from a maximum of 62.4 to a minimum of 5.5. These products did not share a common sun-filter composition, and some CROs used low and others high irradiation dose regimens. When comparing these two regimens, test products fell into two categories: (i) they either behaved similarly ("linear") or (ii) they behaved differently ("exponential"). In the outdoor clinical study, exponential and linear sunscreens did not differ in their photoprotection capacities.

CONCLUSION

Differences in reported SPF values depend on the linear vs exponential behaviour of such products if subjected to low- vs high-dose test regimens. Under real-time exposure to natural sunlight, exponential and linear sunscreens did not differ in their erythema prevention capacity. Laboratory SPF testing of exponential sunscreens bears the risk of underestimating their in-use SPF.

Для цитирования: Trullàs Carles, Granger Corinne, Lim Henry W, Krutmann Jean, Masson Philippe. Linear and exponential sunscreen behaviours as an explanation for observed discrepancies in sun protection factor testing.. Photodermatology, photoimmunology & photomedicine. 2019. DOI: 10.1111/phpp.12500.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.