MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-014-0347-4

Медицинская библиотека · Japanese journal of radiology · 2014

Utility of an initial adaptive bladder volume control with ultrasonography for proton-beam irradiation for prostate cancer.

Takamatsu Shigeyuki, Yamamoto Kazutaka, Kawamura Mariko, Sato Yoshitaka, Asahi Satoko, Kondou Tamaki, Tameshige Yuuji, Maeda Yoshikazu, Sasaki Makoto, Kumano Tomoyasu, Gabata Toshifumi

СтатьяTechnical ReportПеревод пока не подготовлен

Аннотация

PURPOSE: Our purpose was to evaluate the utility of time-fixed bladder volume control and adaptive bladder volume control with ultrasonography (US).

MATERIALS AND

METHODS

Seventy-five patients with prostate cancer treated with proton-beam therapy were enrolled. Treatment plans were created using computed tomography (CT) images obtained 60 min after urination with usual water intake. Just before each irradiation, bladder volume was measured with US at the directed urine collection time. Bladder volume was calculated according to orthogonal diameters. A bladder volume of <50 ml was considered to reflect a collapsed bladder. The percentage of collapsed bladders was examined in total and from the first to fifth irradiations.

RESULTS

In total, 1,439 US confirmations (51 %) in 2,821 fractions were obtained and analyzed. A collapsed bladder was observed 152 of 1,439 times (11 %) in total, and the percentages of collapsed bladders from the first to fifth irradiations were 32 %, 18 %, 16 %, 12 %, and 7 %, respectively.

CONCLUSION

Time-fixed bladder control is associated with a risk of bladder volume insufficiency. Adaptive bladder volume control with initial US feedback could decrease the risk of bladder volume insufficiency.

Для цитирования: Takamatsu Shigeyuki, Yamamoto Kazutaka, Kawamura Mariko, Sato Yoshitaka, Asahi Satoko, Kondou Tamaki, Tameshige Yuuji, Maeda Yoshikazu, Sasaki Makoto, Kumano Tomoyasu, Gabata Toshifumi. Utility of an initial adaptive bladder volume control with ultrasonography for proton-beam irradiation for prostate cancer.. Japanese journal of radiology. 2014. DOI: 10.1007/s11604-014-0347-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.