Physiological effects of lung-protective ventilation in patients with lung fibrosis and usual interstitial pneumonia pattern versus primary ARDS: a matched-control study.

Tonelli Roberto, Grasso Salvatore, Cortegiani Andrea, Ball Lorenzo, Castaniere Ivana, Tabbì Luca, Fantini Riccardo, Andrisani Dario, Gozzi Filippo, Moretti Antonio, Bruzzi Giulia, Manicardi Linda, Cerri Stefania, Samarelli Anna Valeria, Raineri Giulia, Murgolo Francesco, Carzoli Andrea, Di Mussi Rossella, Busani Stefano, Rizzoni Raffaella, Grasselli Giacomo, Clini Enrico, Marchioni Alessandro

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Although patients with interstitial pneumonia pattern (ILD-UIP) and acute exacerbation (AE) leading to severe acute respiratory failure may require invasive mechanical ventilation (MV), physiological data on lung mechanics during MV are lacking. We aimed at describing the physiological effect of lung-protective ventilation in patients with AE-ILD-UIP compared with primary ARDS.

METHODS

Partitioned lung and chest wall mechanics were assessed in a series of AE-ILD-UIP patients matched 1:1 with primary ARDS as controls (based on BMI and PaO2/FiO2 ratio). Three PEEP levels (zero = ZEEP, 4-8 cmH2O = PEEPLOW, and titrated to achieve positive end-expiratory transpulmonary pressure PL,EE = PEEPTITRATED) were used for measurements.

RESULTS

Ten AE-ILD-UIP patients and 10 matched ARDS were included. In AE-ILD-UIP median PL,EE at ZEEP was - 4.3 [- 7.6- - 2.3] cmH2O and lung elastance (EL) 44 [40-51] cmH2O/L. At PEEPLOW, PL,EE remained negative and EL did not change (p = 0.995) versus ZEEP. At PEEPTITRATED, PL,EE increased to 0.8 [0.3-1.5] cmH2O and EL to 49 [43-59] (p = 0.004 and p < 0.001 compared to ZEEP and PEEPLOW, respectively). ΔPL decreased at PEEPLOW (p = 0.018) and increased at PEEPTITRATED (p = 0.003). In matched ARDS control PEEP titration to obtain a positive PL,EE did not result in significant changes in EL and ΔPL.

CONCLUSIONS

In mechanically ventilated AE-ILD-UIP patients, differently than in patients with primary ARDS, PEEP titrated to obtain a positive PL,EE significantly worsened lung mechanics.

Для цитирования: Tonelli Roberto, Grasso Salvatore, Cortegiani Andrea, Ball Lorenzo, Castaniere Ivana, Tabbì Luca, Fantini Riccardo, Andrisani Dario, Gozzi Filippo, Moretti Antonio, Bruzzi Giulia, Manicardi Linda, Cerri Stefania, Samarelli Anna Valeria, Raineri Giulia, Murgolo Francesco, Carzoli Andrea, Di Mussi Rossella, Busani Stefano, Rizzoni Raffaella, Grasselli Giacomo, Clini Enrico, Marchioni Alessandro. Physiological effects of lung-protective ventilation in patients with lung fibrosis and usual interstitial pneumonia pattern versus primary ARDS: a matched-control study.. Critical care (London, England). 2023. DOI: 10.1186/s13054-023-04682-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.