MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1183/09031936.02.00299402

Медицинская библиотека · The European respiratory journal · 2002

An overnight comparison of two ventilators used in the treatment of chronic respiratory failure.

Highcock M P, Morrish E, Jamieson S, Shneerson J M, Smith I E

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

Differences between bilevel ventilators used for noninvasive intermittent positive pressure ventilation (NIPPV) have been demonstrated during bench testing. However, there are no clinical studies comparing these machines. The authors have previously shown that the Quantum pressure support ventilator and Sullivan variable positive airway pressure II ST differ in performance during bench testing. To examine the clinical significance of this, these two machines were compared in the overnight treatment of subjects with chronic respiratory failure. Ten clinically-stable subjects with thoracic scoliosis were recruited. The subjects were already established on NIPPV, but none were using either of the ventilators to be tested. After familiarisation, the patients used the two ventilators in random order on consecutive nights. Peripheral oxygen saturation and transcutaneous carbon dioxide tension (Pt,CO2) were measured continuously, and sleep was recorded using polysomnography. There were no significant differences in arterial oxygen saturation, Pt,CO2 or sleep duration and quality between the two nights. Despite previously illustrated variation in laboratory performance, no differences were seen between the two ventilators when comparing overnight gas exchange and sleep in vivo. Further study is required to evaluate the significance of the differences found during bench testing in the clinical setting.

Для цитирования: Highcock M P, Morrish E, Jamieson S, Shneerson J M, Smith I E. An overnight comparison of two ventilators used in the treatment of chronic respiratory failure.. The European respiratory journal. 2002. DOI: 10.1183/09031936.02.00299402.

Предметные рубрики MeSH